Literature DB >> 14719687

Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transform.

Punam K Saha1, Felix W Wehrli.   

Abstract

Trabecular or cancellous bone, the type of bone found in the vertebrae and near the joints of long bones, consists of a network of plates and struts. Accurate measurement of trabecular thickness is of significant interest, for example, to assess the effectiveness of anabolic (bone forming) agents of patients with osteoporosis. Here, we introduce a new fuzzy distance transform (FDT)-based thickness computation method that obviates binary segmentation and that can effectively deal with images acquired at a voxel size comparable to the typical trabecular bone thickness. The method's robustness is shown on the basis of micro-CT images of human trabecular bone, resampled at progressively coarser resolution and after application of rotation and addition of noise as a means to simulate the in vivo situation. Reproducibility of the method is demonstrated with micro-CT images by comparing histograms of thickness within and between data sets and with micro-MRI volume data sets of human volunteers imaged repeatedly. Finally, with in vivo micro-MR images from a prior study in rabbits subjected to corticosteroid exposure, it is demonstrated that short-term treatment resulting in trabecular thinning can be quantified with the new method.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14719687     DOI: 10.1109/TMI.2003.819925

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  41 in total

1.  Performance of μMRI-Based virtual bone biopsy for structural and mechanical analysis at the distal tibia at 7T field strength.

Authors:  Yusuf A Bhagat; Chamith S Rajapakse; Jeremy F Magland; James H Love; Alexander C Wright; Michael J Wald; Hee Kwon Song; Felix W Wehrli
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Evaluation of trabecular microarchitecture in nonosteoporotic postmenopausal women with and without fracture.

Authors:  Richard Kijowski; Michael Tuite; Diane Kruger; Alejandro Munoz Del Rio; Michael Kleerekoper; Neil Binkley
Journal:  J Bone Miner Res       Date:  2012-07       Impact factor: 6.741

3.  Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 tesla field strength.

Authors:  Michael Jeffrey Wald; Jeremy Franklin Magland; Chamith Sudesh Rajapakse; Felix Werner Wehrli
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

4.  A robust algorithm for thickness computation at low resolution and its application to in vivo trabecular bone CT imaging.

Authors:  Yinxiao Liu; Dakai Jin; Cheng Li; Kathleen F Janz; Trudy L Burns; James C Torner; Steven M Levy; Punam K Saha
Journal:  IEEE Trans Biomed Eng       Date:  2014-07       Impact factor: 4.538

5.  Three-dimensional texture analysis of cancellous bone cores evaluated at clinical CT resolutions.

Authors:  Chad Showalter; Bradley D Clymer; Bradford Richmond; Kimerly Powell
Journal:  Osteoporos Int       Date:  2005-09-17       Impact factor: 4.507

Review 6.  Bone fractal analysis.

Authors:  Gian Pietro Feltrin; Roberto Stramare; Diego Miotto; Dario Giacomini; Claudio Saccavini
Journal:  Curr Osteoporos Rep       Date:  2004-06       Impact factor: 5.096

Review 7.  Noninvasive assessment of bone microarchitecture by MRI.

Authors:  Glenn A Ladinsky; Felix W Wehrli
Journal:  Curr Osteoporos Rep       Date:  2006-12       Impact factor: 5.096

8.  Implications of resolution and noise for in vivo micro-MRI of trabecular bone.

Authors:  Charles Q Li; Jeremy F Magland; Chamith S Rajapakse; X Edward Guo; X Henry Zhang; Branimir Vasilic; Felix W Wehrli
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

10.  Skeletal effects of short-term exposure to dexamethasone and response to risedronate treatment studied in vivo in rabbits by magnetic resonance micro-imaging and spectroscopy.

Authors:  Masaya Takahashi; Punam K Saha; Felix W Wehrli
Journal:  J Bone Miner Metab       Date:  2006       Impact factor: 2.626

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.