Literature DB >> 14648251

[Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig].

A Büchter1, J Kleinheinz, U Joos, U Meyer.   

Abstract

The treatment concept of osseointegration is based on a stable embodiment of implants in bone and the maintenance of stability during functional load. A goal of the surgical preparation technique is therefore to obtain a stable and firm implant anchorage. The aim of this study was to evaluate implant stability after different surgical treatment of the bony implantation bed. Thirty cylindrical solid-screw-shaped implants with standard SLA ITI configuration were implanted into the explanted mandibles of five minipigs. The implant sites were prepared either by a conventional burr technique (group A), by burr technique with additional thread cutting (group B), or by the osteotome technique (group C). Primary implant stability was evaluated by resonance frequency analysis and removal torque test. The average value of the resonance frequency analysis (RFA) was 6000+/-469 cycles/s in group A, 5700+/-557 cycles/s in group B, and 5540+/-527 cycles/s in group C. Removal torque values of group A (507+/-57 Nmm) were significantly higher than those of group B (466+/-45 Nmm) and group C (240+/-31 Nmm) (between group A and C p<0.05, group A to B p=0.39, and B to C p<0.05). It can be concluded from this study that the conventional burr technique achieves a statistically significantly better primary bone anchorage than the osteotome technique.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14648251     DOI: 10.1007/s10006-003-0504-x

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  29 in total

1.  Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis.

Authors:  Ulrich Meyer; Dirk Vollmer; Christoph Runte; Christoph Bourauel; Ulrich Joos
Journal:  J Maxillofac Surg       Date:  2001-04

2.  Clinical uses of osteotomes.

Authors:  J Hahn
Journal:  J Oral Implantol       Date:  1999       Impact factor: 1.779

3.  A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.

Authors:  B Friberg; L Sennerby; N Meredith; U Lekholm
Journal:  Int J Oral Maxillofac Surg       Date:  1999-08       Impact factor: 2.789

4.  [Mechanical stimulation of osteoblasts in cell culture].

Authors:  U Meyer; M Terodde; U Joos; H P Wiesmann
Journal:  Mund Kiefer Gesichtschir       Date:  2001-05

5.  Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using an osteotome technique.

Authors:  Emeka Nkenke; Frank Kloss; Jörg Wiltfang; Stefan Schultze-Mosgau; Martin Radespiel-Tröger; Kerstin Loos; Friedrich Wilhelm Neukam
Journal:  Clin Oral Implants Res       Date:  2002-12       Impact factor: 5.977

6.  Sinus elevation procedures in the resorbed posterior maxilla. Comparison of the crestal and lateral approaches.

Authors:  N U Zitzmann; P Schärer
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-01

7.  The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia.

Authors:  N Meredith; F Shagaldi; D Alleyne; L Sennerby; P Cawley
Journal:  Clin Oral Implants Res       Date:  1997-06       Impact factor: 5.977

8.  [The compressed autogenous spongiosis transplant (author's transl)].

Authors:  C Burri; D Wolter
Journal:  Unfallheilkunde       Date:  1977-05

9.  Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens.

Authors:  B Friberg; L Sennerby; J Roos; U Lekholm
Journal:  Clin Oral Implants Res       Date:  1995-12       Impact factor: 5.977

10.  Effects of barrier membranes on bone resorption and implant stability in onlay bone grafts. An experimental study.

Authors:  L Rasmusson; N Meredith; K E Kahnberg; L Sennerby
Journal:  Clin Oral Implants Res       Date:  1999-08       Impact factor: 5.977

View more
  3 in total

1.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

2.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

3.  Combined effect of undersized surgical technique and axial compression on the primary implant stability and host bone architecture.

Authors:  Afsheen Tabassum; Gert J Meijer; Vincent M J I Cuijpers; X Frank Walboomers
Journal:  Saudi Dent J       Date:  2020-03-19
  3 in total