Literature DB >> 9586468

The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia.

N Meredith1, F Shagaldi, D Alleyne, L Sennerby, P Cawley.   

Abstract

The aim of this investigation was to measure the resonance frequency of a number of implants placed in the rabbit tibia at insertion and at predetermined periods thereafter and to correlate the results with histomorphometric measurements made when the animals were sacrificed. Ten mature New Zealand White rabbits were used in the study. Two c.p. threaded titanium implants were placed in the right tibia of each animal. Resonance frequency measurements were made by screwing a small transducer onto a standard abutment mounted on each fixture. Measurements were repeated with the transducer oriented perpendicular and parallel to the long axis of the tibia for all proximal implants 14 and 28 days after placement and in 6 implants additionally at 42, 56, 93, 122 and 168 days after which all animals were sacrificed. Histomorphometric analysis comprised 2 parts; measurement of bone-implant contact area and height. A significant increase in resonance frequency was observed after 14 (405 Hz, +/- 234 Hz) and 28 (658 Hz, +/- 332 Hz) days. The increase in resonance frequency levelled after approximately 40 days and little further change was observed. The variation in bone-implant contact area was relatively small (1.8-4.9 mm2) and the range of bone-implant contact heights was also narrow (-1.5 (-)+ 1.5 mm). Values for resonance frequencies plotted against contact area and height were grouped around 10 kHz. In conclusion, it was shown that resonance frequency measurements can be made at placement and during healing in vivo and changes may be related to the increase in stiffness of an implant in the surrounding tissues.

Entities:  

Mesh:

Year:  1997        PMID: 9586468     DOI: 10.1034/j.1600-0501.1997.080310.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  44 in total

1.  [Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig].

Authors:  A Büchter; J Kleinheinz; U Joos; U Meyer
Journal:  Mund Kiefer Gesichtschir       Date:  2003-10-24

2.  Natural frequency assessment of stability of root keeper magnetic devices.

Authors:  H M Huang; D Z Liu; Y Y Shiau; C Y Yeh; C T Lin; S Y Lee
Journal:  Med Biol Eng Comput       Date:  2004-05       Impact factor: 2.602

3.  Relation between insertion torque and bone-implant contact percentage: an artificial bone study.

Authors:  Cheng Liu; Ming-Tzu Tsai; Heng-Li Huang; Michael Yuan-Chien Chen; Jui-Ting Hsu; Kuo-Chih Su; Chih-Han Chang; Aaron Yu-Jen Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

4.  Immediate vs non-immediate loading post-extractive implants: a comparative study of implant stability quotient (ISQ).

Authors:  L Milillo; C Fiandaca; F Giannoulis; L Ottria; A Lucchese; F Silvestre; M Petruzzi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

5.  Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical study.

Authors:  Joelle Marie García-Morales; Pedro Tortamano-Neto; Francisco Fernando Todescan; José Carlos Silva de Andrade; Juliana Marotti; Denise Maria Zezell
Journal:  Lasers Med Sci       Date:  2011-07-06       Impact factor: 3.161

6.  Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach.

Authors:  Min Zhai; Bing Li; Dehua Li
Journal:  Med Biol Eng Comput       Date:  2017-02-07       Impact factor: 2.602

7.  Predictive values of resonance frequency analysis as a diagnostic tool in palatal implant loss.

Authors:  Katja Wieczorek; Winfried Harzer; Heinrich Wehrbein; Maximilian Moergel; Martin Kunkel; Britta A Jung
Journal:  Angle Orthod       Date:  2019-03-18       Impact factor: 2.079

8.  Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs.

Authors:  Dong-Seok Kim; Dae-Gon Kim; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

9.  Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.

Authors:  Jung-Woo Koh; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

10.  A comparison of the implant stability among various implant systems: clinical study.

Authors:  Jae-Min Kim; Sun-Jong Kim; Inho Han; Sang-Wan Shin; Jae-Jun Ryu
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.