Literature DB >> 1461210

Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays.

L E Antonuk1, J Boudry, W Huang, D L McShan, E J Morton, J Yorkston, M J Longo, R A Street.   

Abstract

Flat-panel imagers consisting of the first large area, self-scanning, pixelated, solid-state arrays made with hydrogenated amorphous silicon (a-Si:H) are under development by the authors for applications in diagnostic x-ray and megavoltage radiotherapy imaging. The arrays, designated by the acronym MASDA for multi-element amorphous silicon detector array, consist of a two-dimensional array of a-Si:H photodiodes and thin-film transistors and are used in conjunction with scintillating materials. Imagers utilizing MASDA arrays offer a variety of advantages over existing technologies. This article presents initial megavoltage and diagnostic-quality x-ray images taken with several such arrays including the first examples of anatomical-phantom images. The external readout electronics and imaging techniques required to obtain such images are outlined, the construction, operation, and advantages of the arrays briefly reviewed, and the future potential of this new technology discussed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1461210     DOI: 10.1118/1.596802

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging.

Authors:  Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Yi Wang; Hong Du; Amit Sawant; Zhong Su; Jin Yamamoto
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2.

Authors:  Hong Du; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Zhong Su; Jin Yamamoto; Yi Wang
Journal:  Phys Med Biol       Date:  2008-02-14       Impact factor: 3.609

3.  Quality assurance for kilo- and megavoltage in-room imaging and localization for off- and online setup error correction.

Authors:  James M Balter; Larry E Antonuk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008       Impact factor: 7.038

Review 4.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

5.  Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors.

Authors:  Martin Koniczek; Larry E Antonuk; Youcef El-Mohri; Albert K Liang; Qihua Zhao
Journal:  Med Phys       Date:  2017-05-22       Impact factor: 4.071

Review 6.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

7.  Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging.

Authors:  Hao Jiang; Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Tapan Gupta
Journal:  Phys Med Biol       Date:  2013-01-14       Impact factor: 3.609

8.  Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy.

Authors:  Tilman Bostel; Asja Pfaffenberger; Stefan Delorme; Constantin Dreher; Gernot Echner; Peter Haering; Clemens Lang; Mona Splinter; Frederik Laun; Marco Müller; Oliver Jäkel; Jürgen Debus; Peter E Huber; Florian Sterzing; Nils H Nicolay
Journal:  Strahlenther Onkol       Date:  2018-01-18       Impact factor: 3.621

9.  Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers.

Authors:  Langechuan Liu; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Hao Jiang
Journal:  Phys Med Biol       Date:  2012-08-01       Impact factor: 3.609

10.  Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose delivery.

Authors:  S Timothy Peace Balasingh; I Rabi Raja Singh; K Mohamathu Rafic; S Ebenezer Suman Babu; B Paul Ravindran
Journal:  J Med Phys       Date:  2015 Jul-Sep
View more