Literature DB >> 9227231

The impact of cardiology on the collective effective dose in the North of England.

D A Broadhead1, C L Chapple, K Faulkner, M L Davies, H McCallum.   

Abstract

Two cardiology X-ray rooms were monitored with dose-area product meters as part of a Regional Patient Dosimetry Programme. Dose-area product measurements on over 2000 patients undergoing examinations in the cardiology rooms are presented. The data have been corrected according to patient size where possible. In room A mean dose-area product values for coronary angiography, coronary angioplasty, radiofrequency ablation and mitral valvuloplasty were found to be 47.7, 72.2, 91.1 and 161.9 Gy cm2 respectively. In room B mean dose-area product values for coronary angiography and coronary angioplasty were found to be 23.4 and 51.6 Gy cm2 respectively. Observational studies were used to deduce the typical projections and technique factors. This typical examination was used to simulate an angiogram from which it was possible to derive factors to convert measured dose-area product values into estimates of effective dose. In room A, the effective doses were estimated to be 9.4, 14.2, 17.3 and 29.3 mSv for coronary angiography, coronary angioplasty, radiofrequency ablation and mitral valvuloplasty, respectively. The effective doses during coronary angiography and coronary angioplasty, performed in room B, were found to be 4.6 and 10.2 mSv, respectively. A regional survey of the frequency of these cardiac procedures was performed. It was deduced that the annual collective effective dose from these cardiac procedures in the North of England, the former Northern Region, was 45.7 manSv.

Entities:  

Mesh:

Year:  1997        PMID: 9227231     DOI: 10.1259/bjr.70.833.9227231

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

1.  Detection of a double right coronary artery with 16-row multidetector computed tomography.

Authors:  Stefan P Lemburg; Soeren A Peters; Michael Scheeler; Volkmar Nicolas; Christoph M Heyer
Journal:  Int J Cardiovasc Imaging       Date:  2006-08-22       Impact factor: 2.357

2.  Cardiac catheterisation: radiation doses and lifetime risk of malignancy.

Authors:  Kunadian Vijayalakshmi; Dee Kelly; Claire-Louise Chapple; David Williams; Robert Wright; Michael J Stewart; James A Hall; Andrew Sutton; Adrian Davies; John Haywood; Mark A de Belder
Journal:  Heart       Date:  2007-03       Impact factor: 5.994

3.  Effect of kVp on image quality and accuracy in coronary CT angiography according to patient body size: a phantom study.

Authors:  Sang Min Lee; Whal Lee; Jin Wook Chung; Eun-Ah Park; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-02       Impact factor: 2.357

4.  The contribution of interventional cardiology procedures to the population radiation dose in a 'health-care level I' representative region.

Authors:  Andrea Peruzzo Cornetto; Stefania Aimonetto; Francesco Pisano; Marcello Giudice; Marco Sicuro; Teodoro Meloni; Santi Tofani
Journal:  Radiat Prot Dosimetry       Date:  2015-05-25       Impact factor: 0.972

5.  Preliminary reference levels in interventional cardiology.

Authors:  V Neofotistou; E Vano; R Padovani; J Kotre; A Dowling; M Toivonen; S Kottou; V Tsapaki; S Willis; G Bernardi; K Faulkner
Journal:  Eur Radiol       Date:  2003-02-20       Impact factor: 5.315

Review 6.  The Growing Culture Of A Minimally Fluoroscopic Approach In Electrophysiology Lab.

Authors:  Michela Casella; Eleonora Russo; Francesca Pizzamiglio; Sergio Conti; Ghaliah Al-Mohani; Daniele Colombo; Victor Casula; Yuri D Alessandra; Viviana Biagioli; Corrado Carbucicchio; Stefania Riva; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Vittoria Marino; Giovanni Forleo; Pasquale Santangeli; Luigi Di Biase; Antonio Dello Russo; Andrea Natale; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2014-08-31

7.  Retrospective study of patients radiation dose during cardiac catheterization procedures.

Authors:  Beverley Osei; Lu Xu; Amanda Johnston; Sara Darko; Johnson Darko; Ernest Osei
Journal:  Br J Radiol       Date:  2019-05-14       Impact factor: 3.039

8.  Optimization and audit of radiation dose during percutaneous transluminal coronary angioplasty.

Authors:  Roshan S Livingstone; B S Timothy Peace; Sunil Chandy; Paul V George; Purendra Pati
Journal:  J Med Phys       Date:  2007-10

9.  Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector.

Authors:  Anna Varghese; Roshan S Livingstone; Lijo Varghese; Parveen Kumar; Sirish Chandra Srinath; Oommen K George; Paul V George
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

10.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.