Literature DB >> 14529211

Helical cardiac cone beam reconstruction using retrospective ECG gating.

M Grass1, R Manzke, T Nielsen, P Koken, R Proksa, M Natanzon, G Shechter.   

Abstract

In modern computer tomography (CT) systems, the fast rotating gantry and the increased detector width enable 3D imaging of the heart. Cardiac volume CT has a high potential for non-invasive coronary angiography with high spatial resolution and short scan time. Due to the increased detector width, true cone beam reconstruction methods are needed instead of adapted 2D reconstruction schemes. In this paper, the extended cardiac reconstruction method is introduced. It integrates the idea of retrospectively gated cardiac reconstruction for helical data acquisition into a cone beam reconstruction framework. It leads to an efficient and flexible algorithmic scheme for the reconstruction of single- and multi-phase cardiac volume datasets. The method automatically adapts the number of cardiac cycles used for the reconstruction. The cone beam geometry is fully taken into account during the reconstruction process. Within this paper, results are presented on patient datasets which have been acquired using a 16-slice cone beam CT system.

Entities:  

Mesh:

Year:  2003        PMID: 14529211     DOI: 10.1088/0031-9155/48/18/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom.

Authors:  P G C Begemann; U van Stevendaal; R Manzke; A Stork; F Weiss; C Nolte-Ernsting; M Grass; G Adam
Journal:  Eur Radiol       Date:  2005-01-21       Impact factor: 5.315

2.  Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

Authors:  Emmanuel Coche; Alain Vlassenbroek; Véronique Roelants; William D'Hoore; Franck Verschuren; Louis Goncette; Baudouin Maldague
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

3.  Automatic determination of minimal cardiac motion phases for computed tomography imaging: initial experience.

Authors:  Martin H K Hoffmann; Jonathan Lessick; Robert Manzke; Florian T Schmid; Edward Gershin; Daniel T Boll; Shmuel Rispler; Andrik J Aschoff; Michael Grass
Journal:  Eur Radiol       Date:  2005-07-14       Impact factor: 5.315

4.  Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging.

Authors:  Bénédicte Belge; Emmanuel Coche; Agnès Pasquet; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-03-02       Impact factor: 5.315

5.  Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures.

Authors:  Baodong Liu; James Bennett; Ge Wang; Bruno De Man; Kai Zeng; Zhye Yin; Paul Fitzgerald; Hengyong Yu
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  Effect of novel amplitude/phase binning algorithm on commercial four-dimensional computed tomography quality.

Authors:  Jeffrey R Olsen; Wei Lu; James P Hubenschmidt; Michelle M Nystrom; Paul Klahr; Jeffrey D Bradley; Daniel A Low; Parag J Parikh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-26       Impact factor: 7.038

7.  Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.

Authors:  Philipp G C Begemann; Udo van Stevendaal; Ralph Koester; Andreas H Mahnken; Andreas Koops; Gerhard Adam; Michael Grass; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 7.034

8.  Sequential Turning Acquisition and Reconstruction (STAR) method for four-dimensional imaging of cyclically moving structures.

Authors:  Irina V Larina; Kirill V Larin; Mary E Dickinson; Michael Liebling
Journal:  Biomed Opt Express       Date:  2012-02-24       Impact factor: 3.732

9.  A novel platform simulating irregular motion to enhance assessment of respiration-correlated radiation therapy procedures.

Authors:  Mathew J Fitzpatrick; George Starkschall; Peter Balter; John A Antolak; Thomas Guerrero; Christopher Nelson; Paul Keall; Radhe Mohan
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.