Sensitivity, resolution and image quality with a multi-head SPECT camera.

F H Fahey1, B A Harkness, J W Keyes, M T Madsen, C Battisti, V Zito.   

Abstract

This investigation sought to determine which collimation factors were most important in providing superior image quality with a three-headed SPECT device. The relationship between sensitivity, resolution and SPECT image quality was studied. Two different sets of parallel-hole collimators were used. The ultrahigh-resolution collimators have higher spatial resolution (8.9 versus 11.0 mm), but only 55% of the sensitivity of the high-resolution collimators. A phantom with hot rods was imaged with both collimator sets. Observers compared images with the ultrahigh-resolution collimators to images of varying counts with the high-resolution collimators and determined which high-resolution images matched the ultrahigh-resolution images in image quality. Eleven patient studies were acquired with both collimator sets for equal time, and observers chose which image set they preferred. Transverse images of brain and liver studies were simulated with varying resolution and counts and subjectively compared. The phantom study indicated that the improvement in resolution led to image quality comparable to increasing the number of counts by a factor of 2.5 to 3.4. The clinical studies showed that the ultrahigh-resolution collimators were preferred in a large majority of the cases. These trends were also seen in the simulation study. These results confirm that higher resolution collimators should be used with multihead SPECT devices. The improvement in resolution more than compensates for the loss in sensitivity, leading to an overall improvement in image quality.

Entities:  

Mesh:

Year:  1992        PMID: 1403159

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  9 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Stimulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffmann brain phantom: collimator and filter selection in SPECT neuroimaging.

Authors:  H J Kim; J S Karp; P D Mozley; S O Yang; D H Moon; H F Kung; H K Lee; A Alavi
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

Review 3.  Multiheaded rotating gamma cameras in cardiac single-photon emission computed tomographic imaging.

Authors:  T L Faber
Journal:  J Nucl Cardiol       Date:  1994 May-Jun       Impact factor: 5.952

Review 4.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

5.  Optimum tomographic reconstruction parameters for HMPAO brain SPET imaging: a practical approach based on subjective and objective indexes.

Authors:  P O Kotzki; D Mariano-Goulart; M Quiquere; F Lyonnet; M Zanca; M Rossi
Journal:  Eur J Nucl Med       Date:  1995-07

Review 6.  Multidetector single-photon emission tomography: are two (or three or four) heads really better than one?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1993-05

7.  201TL SPECT for evaluating head and neck cancer.

Authors:  S Nagamachi; H Hoshi; S Jinnouchi; T Ohnishi; L G Flores; S Futami; H Nakahara; K Watanabe
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

8.  The Effect of an Energy Window with an Ellipsoid Phantom on the Differential Defect Contrast on Myocardial SPECT Images.

Authors:  Ammar A Oglat; Mohannad Adel Sayah
Journal:  Bioengineering (Basel)       Date:  2022-07-26

9.  PET-Guided Surgery - High Correlation between Positron Emission Tomography with 11C-5-Hydroxytryptophane (5-HTP) and Surgical Findings in Abdominal Neuroendocrine Tumours.

Authors:  Håkan Orlefors; Anders Sundin; Barbro Eriksson; Britt Skogseid; Kjell Oberg; Göran Akerström; Per Hellman
Journal:  Cancers (Basel)       Date:  2012-02-08       Impact factor: 6.639

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.