Multiheaded rotating gamma cameras can do more than simply decrease the time required for cardiac single-photon emission computed tomographic (SPECT) acquisitions. They give their users a flexibility to improve image quality that cannot be achieved so easily with single-headed systems. Multiheaded cameras can be used to acquire quickly those radiopharmaceuticals whose distributions washout very rapidly, increase count levels in noisy images without lengthening imaging time, permit high-resolution collimation or electrocardiographic gating with little or no decrease in counts, or acquire transmission images for attenuation correction concurrently with an emission study. This new generation of SPECT scanners gives the nuclear cardiology community a unique opportunity to create a new generation of cardiac SPECT images.

Mesh:

Year:  1994        PMID: 9420712     DOI: 10.1007/bf02940343

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  25 in total

1.  Sensitivity, resolution and image quality with a multi-head SPECT camera.

Authors:  F H Fahey; B A Harkness; J W Keyes; M T Madsen; C Battisti; V Zito
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

2.  SPECT quantification: a simplified method of attenuation and scatter correction for cardiac imaging.

Authors:  J R Galt; S J Cullom; E V Garcia
Journal:  J Nucl Med       Date:  1992-12       Impact factor: 10.057

3.  Correction of nonuniform attenuation in cardiac SPECT imaging.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; J G Ballard; J R Perry; W H McCartney; J Berg
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

4.  Multidetector SPECT scanner for brain and body: system performance and applications.

Authors:  Y Yonekura; T Fujita; S Nishizawa; T Mukai; H Koide; K Yamamoto; N Tamaki; J Konishi; Y Hirose
Journal:  J Comput Assist Tomogr       Date:  1989 Jul-Aug       Impact factor: 1.826

5.  Tomographic gated blood pool radionuclide ventriculography: analysis of wall motion and left ventricular volumes in patients with coronary artery disease.

Authors:  J R Corbett; D E Jansen; S E Lewis; G I Gabliani; P Nicod; N G Filipchuk; G A Redish; M S Akers; C L Wolfe; J S Rellas
Journal:  J Am Coll Cardiol       Date:  1985-08       Impact factor: 24.094

6.  Artifacts in camera based single photon emission tomography due to time activity variation.

Authors:  B D Bok; A N Bice; M Clausen; D F Wong; H N Wagner
Journal:  Eur J Nucl Med       Date:  1987

7.  Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi.

Authors:  E V Garcia; C D Cooke; K F Van Train; R Folks; J Peifer; E G DePuey; J Maddahi; N Alazraki; J Galt; N Ezquerra
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

8.  Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera.

Authors:  T Chua; H Kiat; G Germano; K Takemoto; G Fernandez; Y Biasio; J Friedman; D Berman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

9.  Performance evaluation of SPRINT, a single photon ring tomography for brain imaging.

Authors:  W L Rogers; N H Clinthorne; J Stamos; K F Koral; R Mayans; G F Knoll; J Juni; J W Keyes; B A Harkness
Journal:  J Nucl Med       Date:  1984-09       Impact factor: 10.057

10.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion.

Authors:  R Eisner; A Churchwell; T Noever; D Nowak; K Cloninger; D Dunn; W Carlson; J Oates; J Jones; D Morris
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

View more
  1 in total

Review 1.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.

Authors:  M A King; B M Tsui; T S Pan
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952