Literature DB >> 1396876

Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor.

L Pace1, A Cuocolo, A Nappi, E Nicolai, B Trimarco, M Salvatore.   

Abstract

The accuracy and repeatability of a new ambulatory radionuclide detector (VEST) for left ventricular systolic (ejection fraction) and diastolic (peak filling rate) measurements were assessed. Seventeen patients underwent equilibrium radionuclide angiography immediately before and immediately after a VEST study. The accuracy was evaluated at the beginning and at the end of the VEST studies. Limits of agreement for the ejection fraction were -1%:2% at the beginning of the VEST study and -4%:4% at the end. Limits of agreement for the peak filling rate were -0.6:0.6 at the beginning of the VEST study and -0.7:0.5 at the end. For both measurements the limits of agreement were well within the clinical range. Repeatability was evaluated in a second group of 11 patients who underwent VEST studies in 2 separate days. The coefficient of repeatability (twice the standard deviation of the differences between the 2 studies) was 13 for the ejection fraction and 0.4 for the peak filling rate. Thus, the VEST is an accurate and repeatable method to measure both the ejection fraction and peak filling rate.

Entities:  

Mesh:

Year:  1992        PMID: 1396876     DOI: 10.1007/bf00182823

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  17 in total

1.  Accuracy and reproducibility of left ventricular ejection fraction measurements using an ambulatory radionuclide left ventricular function monitor.

Authors:  L de Yang; C N Bairey; D S Berman; K J Nichols; T Odom-Maryon; A Rozanski
Journal:  J Nucl Med       Date:  1991-05       Impact factor: 10.057

2.  Continuous monitoring of left ventricular function by an ambulatory radionuclide detector in patients with coronary artery disease.

Authors:  N Tamaki; T Yasuda; R H Moore; J B Gill; C A Boucher; A M Hutter; H K Gold; H W Strauss
Journal:  J Am Coll Cardiol       Date:  1988-09       Impact factor: 24.094

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  An ambulatory ventricular function monitor: validation and preliminary clinical results.

Authors:  R A Wilson; P J Sullivan; R H Moore; J S Zielonka; N M Alpert; C A Boucher; K A McKusick; H W Strauss
Journal:  Am J Cardiol       Date:  1983-09-01       Impact factor: 2.778

5.  Failure of antihypertensive therapy with diuretic, beta-blocking and calcium channel-blocking drugs to consistently reverse left ventricular diastolic filling abnormalities.

Authors:  I K Inouye; B M Massie; D Loge; P Simpson; J F Tubau
Journal:  Am J Cardiol       Date:  1984-06-01       Impact factor: 2.778

6.  Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography.

Authors:  R O Bonow; S L Bacharach; M V Green; K M Kent; D R Rosing; L C Lipson; M B Leon; S E Epstein
Journal:  Circulation       Date:  1981-08       Impact factor: 29.690

7.  Comparison of physiologic ejection fraction responses to activities of daily living: implications for clinical testing.

Authors:  C N Bairey; L de Yang; D S Berman; A Rozanski
Journal:  J Am Coll Cardiol       Date:  1990-10       Impact factor: 24.094

8.  Effects of verapamil on left ventricular systolic function and diastolic filling in patients with hypertrophic cardiomyopathy.

Authors:  R O Bonow; D R Rosing; S L Bacharach; M V Green; K M Kent; L C Lipson; B J Maron; M B Leon; S E Epstein
Journal:  Circulation       Date:  1981-10       Impact factor: 29.690

9.  Intact systolic left ventricular function in clinical congestive heart failure.

Authors:  R Soufer; D Wohlgelernter; N A Vita; M Amuchestegui; H D Sostman; H J Berger; B L Zaret
Journal:  Am J Cardiol       Date:  1985-04-01       Impact factor: 2.778

10.  Effects of intravenous verapamil administration on left ventricular diastolic function in systemic hypertension.

Authors:  S Betocchi; A Cuocolo; L Pace; M Chiariello; B Trimarco; B Alfano; B Ricciardelli; M Salvatore; M Condorelli
Journal:  Am J Cardiol       Date:  1987-03-01       Impact factor: 2.778

View more
  10 in total

1.  Radionuclide monitoring of left ventricular function after sublingual nifedipine administration at rest and during moderate physical activity.

Authors:  A Ferro; M Salvatore; A Cuocolo
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

2.  Hemodynamic effects of isometric exercise in hypertrophic cardiomyopathy: comparison with normal subjects.

Authors:  Quirino Ciampi; Sandro Betocchi; Anna Violante; Raffaella Lombardi; Maria Angela Losi; Giovanni Storto; Fiore Manganelli; Carlo Gabriele Tocchetti; Mariano Aversa; Elpidio Pezzella; Filippo Finizio; Alberto Cuocolo; Massimo Chiariello
Journal:  J Nucl Cardiol       Date:  2003 Mar-Apr       Impact factor: 5.952

3.  Early and late effects of coronary artery bypass grafting on cardiac haemodynamics during daily physical activities in patients with coronary artery disease.

Authors:  Massimo Imbriaco; Adele Ferro; Giovanni Storto; Teresa Pellegrino; Giacomo Sica; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02-03       Impact factor: 9.236

4.  Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function.

Authors:  Adele Ferro; Carlo Duilio; Maurizio Santomauro; Marco Salvatore; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-13       Impact factor: 9.236

5.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

6.  Assessment of left ventricular volume by an ambulatory radionuclide monitoring system during head-up tilt in patients with unexplained syncope: relation to autonomic activity assessed by heart rate variability.

Authors:  H Hosaka; B Takase; K Kitamura; A Uehata; K Satomura; K Isojima; S Kosuda; S Kusano; A Kurita; F Ohsuzu
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

7.  Ambulatory monitoring of left ventricular function in patients with Parkinson's disease and postural hypotension.

Authors:  A Nappi; A Cuocolo; N Iazzetta; L A Ferrara; T Marotta; L Pace; E Nicolai; G De Michele; G Campanella; M Salvatore
Journal:  Eur J Nucl Med       Date:  1994-12

8.  Abnormal blood-pressure response to exercise and oxygen consumption in patients with hypertrophic cardiomyopathy.

Authors:  Quirino Ciampi; Sandro Betocchi; Maria Angela Losi; Adele Ferro; Alberto Cuocolo; Raffaella Lombardi; Bruno Villari; Massimo Chiariello
Journal:  J Nucl Cardiol       Date:  2007-10-22       Impact factor: 5.952

9.  Left ventricular end-diastolic volume is decreased at maximal exercise in athletes with marked repolarisation abnormalities: a continuous radionuclide monitoring study.

Authors:  Albert Flotats; Ricard Serra-Grima; Valle Camacho; Esther Mena; Xavier Borràs; Montserrat Estorch; Ana Tembl; Jordi Fuertes; Juan Cinca; Ignasi Carrió
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-09-16       Impact factor: 9.236

10.  Assessment of the optimal atrioventricular delay in dual chamber-paced patients by a portable scintillation probe (VEST).

Authors:  L Mortelmans; W Vanhecke; D Mertens; H Ector; C Timmermans; M De Roo; H De Geest; F Van de Werf
Journal:  J Nucl Cardiol       Date:  1996 Jul-Aug       Impact factor: 5.952

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.