Accuracy and reproducibility of left ventricular ejection fraction measurements using an ambulatory radionuclide left ventricular function monitor.

L de Yang1, C N Bairey, D S Berman, K J Nichols, T Odom-Maryon, A Rozanski.   

Abstract

The accuracy and reproducibility of a new ambulatory radionuclide detector system (the VEST) for ejection fraction measurement has not been fully validated. Thirty-six subjects, (19 volunteers and 17 patients) underwent repetitive bicycle exercise using sequences of both VEST monitoring and gamma camera imaging. A high intraclass correlation was noted for both absolute ejection fraction [0.84 (0.56, 0.95)] and delta ejection fraction [0.87 (0.63, 0.96)] during repeat VEST monitoring. The intraclass correlation for ejection fraction was comparable for data averaged over 30 sec versus 2 min. These correlations compared favorably to those obtained for assessment of absolute and delta ejection fraction as derived by gamma camera determination by the same computer operator (intraobserver variability), two different computer operators (interobserver variability), and during repeat exercise using gamma camera imaging. In concordance, correlations between VEST and gamma camera measurements were relatively high for both absolute ejection fraction (0.78 [0.61, 0.88]) and delta ejection fraction (0.63 [0.39, 0.79]). Thus, the VEST represents a reproducible means of measuring ejection fraction change during dynamic physical activity. Its accuracy in ejection fraction measurements is similar to gamma camera imaging during exercise testing.

Entities:  

Mesh:

Year:  1991        PMID: 2022984

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  9 in total

1.  Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor.

Authors:  L Pace; A Cuocolo; A Nappi; E Nicolai; B Trimarco; M Salvatore
Journal:  Eur J Nucl Med       Date:  1992

2.  EANM/ESC guidelines for radionuclide imaging of cardiac function.

Authors:  B Hesse; T B Lindhardt; W Acampa; C Anagnostopoulos; J Ballinger; J J Bax; L Edenbrandt; A Flotats; G Germano; T Gmeiner Stopar; P Franken; A Kelion; A Kjaer; D Le Guludec; M Ljungberg; A F Maenhout; C Marcassa; J Marving; F McKiddie; W M Schaefer; L Stegger; R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-04       Impact factor: 9.236

3.  Nonperfusion applications in nuclear cardiology: report of a task force of the American Society of Nuclear Cardiology.

Authors:  E G DePuey; S Port; F J Wackers; A Rozanski; E H Botvinick; M W Dae; N Tamaki
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

4.  Ambulatory monitoring of left ventricular function in patients with Parkinson's disease and postural hypotension.

Authors:  A Nappi; A Cuocolo; N Iazzetta; L A Ferrara; T Marotta; L Pace; E Nicolai; G De Michele; G Campanella; M Salvatore
Journal:  Eur J Nucl Med       Date:  1994-12

5.  Left ventricular end-diastolic volume is decreased at maximal exercise in athletes with marked repolarisation abnormalities: a continuous radionuclide monitoring study.

Authors:  Albert Flotats; Ricard Serra-Grima; Valle Camacho; Esther Mena; Xavier Borràs; Montserrat Estorch; Ana Tembl; Jordi Fuertes; Juan Cinca; Ignasi Carrió
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-09-16       Impact factor: 9.236

6.  Pathophysiology and time course of silent myocardial ischaemia during mental stress: clinical, anatomical, and physiological correlates.

Authors:  S E Legault; M R Freeman; A Langer; P W Armstrong
Journal:  Br Heart J       Date:  1995-03

7.  A system for postoperative visualization and analysis of left ventricular pressure-volume loops.

Authors:  B B Beard; J R Stewart; T A Fischell
Journal:  Comput Biol Med       Date:  1998-01       Impact factor: 4.589

8.  Rate of change of left ventricular ejection fraction during exercise is superior to the peak ejection fraction for predicting functionally significant coronary artery disease.

Authors:  B S Sridhara; S Bhattacharya; X J Liu; P Broadhurst; A Lahiri
Journal:  Br Heart J       Date:  1993-12

9.  Assessment of the optimal atrioventricular delay in dual chamber-paced patients by a portable scintillation probe (VEST).

Authors:  L Mortelmans; W Vanhecke; D Mertens; H Ector; C Timmermans; M De Roo; H De Geest; F Van de Werf
Journal:  J Nucl Cardiol       Date:  1996 Jul-Aug       Impact factor: 5.952

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.