Literature DB >> 3825903

Effects of intravenous verapamil administration on left ventricular diastolic function in systemic hypertension.

S Betocchi, A Cuocolo, L Pace, M Chiariello, B Trimarco, B Alfano, B Ricciardelli, M Salvatore, M Condorelli.   

Abstract

The effects of intravenous verapamil administration (0.1 mg/kg as a bolus followed by an infusion of 0.007 mg/kg/min) were studied using high-temporal-resolution radionuclide angiography in 27 patients with hypertension. Verapamil administration increased heart rate from 69 +/- 11 to 75 +/- 12 beats/min (p less than 0.001) and decreased systolic, diastolic and mean blood pressures (BPs) from 155 +/- 21/102 +/- 12 mm Hg (mean 119 +/- 14) to 142 +/- 19/95 +/- 12 mm Hg (mean 109 +/- 13) (p less than 0.001 for all). Ejection fraction decreased significantly (from 65 +/- 10% to 60 +/- 11%, p less than 0.005); peak filling rate, however, increased significantly only in patients in whom it was subnormal in the basal study (from 2.2 +/- 0.4 to 3.0 +/- 0.6 end-diastolic counts/s, p less than 0.001). These latter patients had significantly higher values of left ventricular (LV) mass index than patients with normal or increased peak filling rate (129 +/- 22 vs 112 +/- 22 g/m2, respectively, p less than 0.05). The isovolumic relaxation period changes were inversely related to the baseline values (r = 0.83, p less than 0.001). In the subgroup of patients in whom isovolumic relaxation period lengthened, time to end systole decreased (from 360 +/- 31 to 329 +/- 30 ms, p less than 0.025) and time to onset of rapid filling increased (from 420 +/- 31 to 451 +/- 34 ms, p less than 0.025), whereas these 2 intervals had opposite patterns in patients in whom isovolumic relaxation period decreased or did not change.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3825903     DOI: 10.1016/0002-9149(87)91181-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor.

Authors:  L Pace; A Cuocolo; A Nappi; E Nicolai; B Trimarco; M Salvatore
Journal:  Eur J Nucl Med       Date:  1992

2.  Quantitation of left ventricular asynchrony on radionuclide angiography phase images.

Authors:  B Alfano; S Betocchi; L Pace; P Perrone-Filardi; M Chiariello; M Salvatore
Journal:  Eur J Nucl Med       Date:  1990

3.  Phase analysis of radionuclide angiography in acute myocardial infarction.

Authors:  D Bonaduce; G Morgano; M Petretta; P Arrichiello; R Breglio; S Betocchi; C Acampora; M Salvatore; M Chiariello
Journal:  Eur J Nucl Med       Date:  1990

Review 4.  Hypertension and diastolic function.

Authors:  E Agabiti-Rosei; M L Muiesan
Journal:  Drugs       Date:  1993       Impact factor: 9.546

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.