[Measurement of the disc area by indirect ophthalmoscopy].

M Haustein1, E Schmidt, E Spörl, L E Pillunat, A G Böhm.   

Abstract

PURPOSE: The aim of this study was to assess the accuracy of measuring the optic disc area by indirect ophthalmoscopy. PATIENTS AND METHODS: In a prospective clinical trial, 57 eyes of 29 subjects (age 57.3+/-12.1 years) were examined. The refractive error was -0.67+/-2.69D (+3.75D to -8D).The vertical and horizontal disc diameters (DD) were measured using a Haag-Streit slit lamp and 60D-, 78D-, 90D-, and Super Field lenses (Volk Optical, Mentor, USA). Afterwards the disc area was calculated by an ellipse formula (horizontal DD x vertical DD x pi/4). The magnification factor given by the manufacturer was taken into account for each lens: 1.15x (60D lens), 0.93x (78D lens), 0.76x (90D lens), and 0.76x (Super Field lens), respectively. As reference for the disc size, the same eyes were examined by HRT II (Heidelberg Engineering, Heidelberg, Germany). Bland-Altman plots were used to assess the agreement between measurements obtained by indirect ophthalmoscopy and HRT.
RESULTS: The results of the disc estimate compared with the HRT measurements were as follows: 0.119+/-0.51 mm(2) (60D lens), 0.224+/-0.57 mm(2) (78D lens), 0.10+/-0.51 mm(2) (90D lens), and -0.07 s+/-0.47 mm(2) (Super Field lens). Differences were not statistically significant for the 60D (p=0.083), 90D (p=0.147), or Super Field lenses (p=0.257). However, the difference between the 78D lens and HRT was statistically significant (Student's t-test; P=0.004).
CONCLUSION: Measuring the disc size by indirect ophthalmoscopy is possible. The 90D lens showed the smallest and the 78D lens the largest deviation.

Entities:  

Mesh:

Year:  2009        PMID: 18546001     DOI: 10.1007/s00347-008-1774-3

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  29 in total

Review 1.  Ophthalmoscopic evaluation of the optic nerve head.

Authors:  J B Jonas; W M Budde; S Panda-Jonas
Journal:  Surv Ophthalmol       Date:  1999 Jan-Feb       Impact factor: 6.048

2.  Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender.

Authors:  Christopher Bowd; Linda M Zangwill; Eytan Z Blumenthal; Cristiana Vasile; Andreas G Boehm; Parag A Gokhale; Kourosh Mohammadi; Payam Amini; Timothy M Sankary; Robert N Weinreb
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2002-01       Impact factor: 2.129

3.  [Healthy optic discs with large cups--a diagnostic challenge in glaucoma].

Authors:  C Y Mardin; F Horn; A Viestenz; R Lämmer; A Jünemann
Journal:  Klin Monbl Augenheilkd       Date:  2006-04       Impact factor: 0.700

4.  Comparison of optic nerve head assessment with a digital stereoscopic camera (discam), scanning laser ophthalmoscopy, and stereophotography.

Authors:  Anthony J Correnti; Gadi Wollstein; Lori Lyn Price; Joel S Schuman
Journal:  Ophthalmology       Date:  2003-08       Impact factor: 12.079

5.  [Effect of the contour line on cup surface using the Heidelberg Retina Tomograph].

Authors:  K U Bartz-Schmidt; C P Jonescu-Cuypers; G Thumann; J Frucht; G K Krieglstein
Journal:  Klin Monbl Augenheilkd       Date:  1996-11       Impact factor: 0.700

6.  Ophthalmoscopic measurement of the optic disc.

Authors:  J B Jonas; K Papastathopoulos
Journal:  Ophthalmology       Date:  1995-07       Impact factor: 12.079

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  [Determination of the real size of an object on the fundus of the living eye].

Authors:  H Littmann
Journal:  Klin Monbl Augenheilkd       Date:  1982-04       Impact factor: 0.700

9.  Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry.

Authors:  D F Garway-Heath; D Poinoosawmy; G Wollstein; A Viswanathan; D Kamal; L Fontana; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1999-06       Impact factor: 4.638

10.  Optic disc diameter influences the ability to detect glaucomatous disc damage.

Authors:  A Heijl; H Mölder
Journal:  Acta Ophthalmol (Copenh)       Date:  1993-02
View more
  1 in total

1.  The fundus slit lamp.

Authors:  Marcus-Matthias Gellrich
Journal:  Springerplus       Date:  2015-02-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.