Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation.

Todd D Stewart1, Joanne L Tipper, Gerard Insley, Robert M Streicher, Eileen Ingham, John Fisher.   

Abstract

The purpose of this study was to evaluate the long-term wear performance of alumina matrix composite (AMC) heads against alumina matrix composite inserts and alumina matrix composite heads against alumina (Al) inserts with the use of a hip-joint simulator incorporating severe swing phase joint microseparation. The wear of AMC on Al produced an average wear rate of 0.61 mm3/million cycles over the 5-million-cycle test duration. The wear of AMC on AMC produced an average wear rate of 0.16 mm3/million cycles over the 5-million-cycle test duration. Both the AMC on alumina and AMC on AMC produced significantly lower wear than previously tested HIPed alumina, where an average wear rate of 1.84 mm3/million cycles was reported over 5 million cycles. The wear mechanisms and wear debris of AMC on AMC and AMC on Al were similar to those observed in previous alumina retrieval studies with stripe wear caused by intragranular fracture and wear debris consisting of predominantly uniform 10-20-nm-sized particles and a few irregular particles up to 3 microm in size. Copyright 2003 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12861609     DOI: 10.1002/jbm.b.10035

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  16 in total

1.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

2.  High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings.

Authors:  J C Keurentjes; R M Kuipers; D J Wever; B W Schreurs
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

3.  Squeaking and microcracks in a delta-delta ceramic coupling: pin-on-disc study.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tadami Matsumoto; Kazuhiro Shintani
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-12

4.  [Which hip articulation bearing for which patient? : Tribology of the future].

Authors:  M M Morlock; N Bishop; C Kaddick
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

5.  Thin hard crest on the edge of ceramic acetabular liners accelerates wear in edge loading.

Authors:  Anthony P Sanders; Parth J Dudhiya; Rebecca M Brannon
Journal:  J Arthroplasty       Date:  2011-10-05       Impact factor: 4.757

6.  Impingement in Total Hip Replacement: Mechanisms and Consequences.

Authors:  Thomas D Brown; John J Callaghan
Journal:  Curr Orthop       Date:  2008-12-01

Review 7.  [Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique].

Authors:  M M Morlock; M Jäger
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

8.  THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial.

Authors:  William G Hamilton; James P McAuley; Douglas A Dennis; Jeffrey A Murphy; Thomas J Blumenfeld; Joel Politi
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

9.  (v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear.

Authors:  John Fisher; Mazen Al Hajjar; Sophie Williams; Joanne Tipper; Eileen Ingham; Louise Jennings
Journal:  Orthop Trauma       Date:  2012-08

10.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Sophie Williams; Joanne L Tipper; Louise M Jennings
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-12-20       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.