Literature DB >> 12838096

A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation.

John Glaser1, Mark Stanley, Hutha Sayre, Joyce Woody, Ernest Found, Kevin Spratt.   

Abstract

STUDY
DESIGN: A retrospective cohort study was conducted.
OBJECTIVE: To evaluate the long-term results of lumbar spine fusion supplemented with pedicle screw fixation. SUMMARY OF BACKGROUND DATA: Pedicle screw fixation of the lumbar spine is widely used, yet there is little long-term follow-up information on the technique.
METHODS: All adult patients treated at the University of Iowa Department of Orthopedic Surgery with lumbar pedicle screw fixation between March 10, 1986 and July 1, 1991 were reviewed. All the patients initially had answered a battery of questions regarding pain and disability and had radiographs performed. At follow-up evaluation, the same and other questions regarding their status were asked, and SF-36 was used. Radiographs were reviewed for evidence of hardware complications, fusion status, deformity, and extent of degeneration around the fusion.
RESULTS: In this study, 234 patients underwent 236 pedicle screw fixation procedures. Indications for surgery were degeneration (n = 127), trauma/instability (n = 33), pseudarthrosis (n = 17), deformity (n = 16), tumor (n = 4), inflammatory process (n = 4), infection (n = 1), and unknown (n = 32). Variable screw placement (Acromed, Cleveland Ohio) fixation was used in all cases. Nonintegral locking nuts were used in 119 cases. Of the 234 patients, 31 had died, 5 had been eliminated because the chart review indicated that their reason for surgery was tumor or infection, and 92 were lost to follow-up evaluation for various reasons. Of the remaining 107 patients, 13 had incomplete data, leaving 94 patients with complete information. The SF-36 showed reports of bodily pain and physical functioning below age- and gender-adjusted means, but disability and function scores demonstrated significant improvement at the 10-year follow-up assessment. Patient-reported satisfaction was high, approximately 80%. Radiographically, at the 10-year follow-up assessment, 242 of 244 instrumented segments showed no motion, with approximately one third of these also showing evidence of definite fusion.
CONCLUSIONS: At a minimum follow-up evaluation of 10 years, lumbar fusion with pedicle screw fixation showed relatively good functional capacity, especially relative to the baseline, a low rate of radiographic failure, satisfaction of patients with their progress, a low rate of repeat surgery, and minimal surgical and hardware-related complications.

Entities:  

Mesh:

Year:  2003        PMID: 12838096     DOI: 10.1097/01.BRS.0000067112.15753.AD

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  23 in total

1.  Biomechanical evaluation of an expansive pedicle screw in calf vertebrae.

Authors:  Wei Lei; Zixiang Wu
Journal:  Eur Spine J       Date:  2005-04-30       Impact factor: 3.134

2.  Dynesys fixation for lumbar spine degeneration.

Authors:  Matthias Bothmann; Erich Kast; Gerald Jens Boldt; Joachim Oberle
Journal:  Neurosurg Rev       Date:  2007-09-29       Impact factor: 3.042

3.  Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis system) with a 13-year mean follow-up.

Authors:  Jacques Sénégas; Jean-Marc Vital; Vincent Pointillart; Paolo Mangione
Journal:  Neurosurg Rev       Date:  2009-04-22       Impact factor: 3.042

4.  Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine.

Authors:  Zhiming Chen; Jie Zhao; Hao Xu; Aigang Liu; Jiandong Yuan; Cong Wang
Journal:  Eur Spine J       Date:  2008-09-16       Impact factor: 3.134

5.  Biomechanical effects of pedicle screw fixation on adjacent segments.

Authors:  Thein Aung Kyaw; Zhuo Wang; Toshihiko Sakakibara; Takamasa Yoshikawa; Tadashi Inaba; Yuichi Kasai
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-22

6.  Correlative radiological, self-assessment and clinical analysis of evolution in instrumented dorsal and lateral fusion for degenerative lumbar spine disease. Autograft versus coralline hydroxyapatite.

Authors:  Panagiotis Korovessis; Georgios Koureas; Spyridon Zacharatos; Zisis Papazisis; Elias Lambiris
Journal:  Eur Spine J       Date:  2005-03-24       Impact factor: 3.134

7.  Results after anterior-posterior lumbar spinal fusion: 2-5 years follow-up.

Authors:  Thomas Niemeyer; Albert Schulze Bövingloh; Henry Halm; Ulf Liljenqvist
Journal:  Int Orthop       Date:  2004-07-27       Impact factor: 3.075

8.  The positive effect of posterolateral lumbar spinal fusion is preserved at long-term follow-up: a RCT with 11-13 year follow-up.

Authors:  Thomas Andersen; Tina S Videbaek; Ebbe S Hansen; Cody Bünger; Finn B Christensen
Journal:  Eur Spine J       Date:  2007-09-12       Impact factor: 3.134

9.  Complications in degenerative lumbar disease treated with a dynamic interspinous spacer (Coflex).

Authors:  Cong Xu; Wen-Fei Ni; Nai-Feng Tian; Xu-Qi Hu; Fan Li; Hua-Zi Xu
Journal:  Int Orthop       Date:  2013-07-27       Impact factor: 3.075

10.  Long-term actuarial survivorship analysis of an interspinous stabilization system.

Authors:  Jacques Sénégas; Jean-Marc Vital; Vincent Pointillart; Paolo Mangione
Journal:  Eur Spine J       Date:  2007-04-11       Impact factor: 3.134

View more