Literature DB >> 12827425

Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance.

Hicham T Abada1, Marc R Sapoval, Jean-François Paul, Viviane de Maertelaer, Elie Mousseaux, Jean-Claude Gaux.   

Abstract

The aim of this study was to determine the variability of various measurement protocols for measurement of abdominal aortic aneurysm (AAA) and the clinical relevance of variability. Three radiologists performed computed tomographic angiography measurements of both the aorta and the largest portion of the aneurysm on selected axial slices. Then measurements of the largest portion of the aneurysm were performed on unselected axial slices, sagittal and coronal reformatted. Finally, aortic volume was calculated. Measurements and volume calculation were performed before and after endovascular repair and assessed: Part 1: interobserver variability for maximum anteroposterior (MAP) and maximum transverse (MTR) diameters on selected slices; part 2: interobserver variability for unselected slices considering MAP and MTR; part 3: interobserver variability considering maximum diameter in any direction (MAD); part 4: interobserver variability for sagittal (SAG) and coronal (COR) free curved multiplanar reformation (MPR); and part 5: volume calculations. We then determined which technique of measurement was the most clinically relevant for detecting changes in aneurysm size or aortic volume. Parts 1 and 2: interobserver variability was 4.1 mm for both MAP and MTR; part 3: interobserver variability was 7 mm for MAD; part 4: interobserver variability was 5.5 mm (COR) and 4.9 mm (SAG); part 5: interobserver variability for volume was 5.5 ml. A combination of MAP and MTR was the most useful for detecting aortic modification. Volume calculation was needed in only a few cases. We recommend avoiding MAD and MPR measurements and suggest instead measuring both maximum anteroposterior and maximum transverse diameters. If aneurysm size remains stable after endovascular repair, aneurysm volume should be measured.

Entities:  

Mesh:

Year:  2003        PMID: 12827425     DOI: 10.1007/s00330-003-1914-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  17 in total

1.  Precise determination of aortic length in patients with aortic stent grafts: in vivo evaluation of a thinning algorithm applied to CT angiography data.

Authors:  H Shin; A Chavan; F Witthus; D Selle; G Stamm; H O Peitgen; M Galanski
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

2.  Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention.

Authors:  R Dorffner; S Thurnher; P Polterauer; G Kretschmer; J Lammer
Journal:  Radiology       Date:  1997-07       Impact factor: 11.105

3.  Measurement error.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-09-21

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Inter- and intraobserver variability of CT measurements obtained after endovascular repair of abdominal aortic aneurysms.

Authors:  J J Wever; J D Blankensteijn; J C van Rijn; I A Broeders; B C Eikelboom; W P Mali
Journal:  AJR Am J Roentgenol       Date:  2000-11       Impact factor: 3.959

Review 6.  Imaging of complications after endoluminal treatment of abdominal aortic aneurysms.

Authors:  J Golzarian; J Struyven
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

7.  Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm.

Authors:  Yehuda G Wolf; Manfred Tillich; W Anthony Lee; Thomas J Fogarty; Christopher K Zarins; Geoffrey D Rubin
Journal:  J Vasc Surg       Date:  2002-08       Impact factor: 4.268

8.  Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts.

Authors:  U Blum; M Langer; G Spillner; C Mialhe; F Beyersdorf; C Buitrago-Tellez; G Voshage; C Düber; V Schlosser; A H Cragg
Journal:  Radiology       Date:  1996-01       Impact factor: 11.105

9.  Accuracy of ultrasound in a screening programme for abdominal aortic aneurysms.

Authors:  P R Thomas; J C Shaw; H A Ashton; D N Kay; R A Scott
Journal:  J Med Screen       Date:  1994-01       Impact factor: 2.136

10.  Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: a progress report.

Authors:  J C Parodi; F J Criado; H D Barone; C Schönholz; L A Queral
Journal:  Ann Vasc Surg       Date:  1994-11       Impact factor: 1.466

View more
  4 in total

1.  Quantification of aortic elasticity: development and experimental validation of a method using computed tomography.

Authors:  Marika Ganten; Jan M Boese; David Leitermann; Wolfhard Semmler
Journal:  Eur Radiol       Date:  2005-07-26       Impact factor: 5.315

2.  On growth measurements of abdominal aortic aneurysms using maximally inscribed spheres.

Authors:  H Gharahi; B A Zambrano; C Lim; J Choi; W Lee; S Baek
Journal:  Med Eng Phys       Date:  2015-05-23       Impact factor: 2.242

3.  Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server.

Authors:  Emanuele Neri; Irene Bargellini; Michael Rieger; Andrea Giachetti; Claudio Vignali; Massimiliano Tuveri; Werner Jaschke; Carlo Bartolozzi
Journal:  Eur Radiol       Date:  2004-10-16       Impact factor: 5.315

4.  Hybrid-repair of thoraco-abdominal or juxtarenal aortic aneurysm: what the radiologist should know.

Authors:  Tobias Krauss; Thomas Pfammatter; Dieter Mayer; Mario Lachat; Lukas Hechelhammer; Borut Marincek; Thomas Frauenfelder
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

  4 in total