Literature DB >> 9205226

Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention.

R Dorffner1, S Thurnher, P Polterauer, G Kretschmer, J Lammer.   

Abstract

PURPOSE: To determine the rate of complications of transluminally placed endovascular stent-grafts in patients with abdominal aortic aneurysms and to assess efficacy of secondary radiologic intervention.
MATERIALS AND METHODS: In 28 patients, covered nitinol stents were implanted. Frequency and outcome of complications were evaluated after stent-graft placement (mean follow-up, 8.2 months).
RESULTS: In 27 patients, 11 tube and 16 bifurcated grafts were implanted successfully. In one (4%) patient, distal migration of a bifurcated graft necessitated conversion to standard open repair. Technical success rates (successful deployment of the device and complete exclusion of the aneurysm at intraoperative angiography) for bifurcated and tube grafts were 24% (four of 17 patients) and 91% (10 of 11 patients). After surgery, leaks were seen in six bifurcated and five tube grafts. After secondary intervention, the final exclusion rate for bifurcated and tube grafts was 88% (15 of 17 patients) and 100% (11 of 11 patients), respectively; the overall success rate was 93% (26 of 28 patients) for exclusion of aortic abdominal aneurysms. Stent-graft thrombosis necessitated local thrombolysis in one patient. Overlapping of accessory renal arteries occurred in two patients.
CONCLUSION: Complications after stent-graft placement in abdominal aortic aneurysms are frequent. Secondary radiologic intervention is successful in most cases.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9205226     DOI: 10.1148/radiology.204.1.9205226

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Unusual complications of endovascular repair of the thoracic aorta: MDCT findings.

Authors:  T Valente; G Rossi; F Lassandro; G Rea; M Marino; G Dialetto; R Muto; M Scaglione
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

2.  Endovascular aneurysm repair.

Authors:  R M Fujitani
Journal:  West J Med       Date:  1998-01

3.  Thrombus originating from frayed distal edge of an aortic stent-graft.

Authors:  Tsuyoshi Taketani; Tetsuro Morota; Ko Shibata; Yutaka Kotsuka; Shinichi Takamoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2004-02

Review 4.  [Endovascular aneurysm repair (EVAR) : Complication management].

Authors:  S Amin; J Schnabel; O Eldergash; A Chavan
Journal:  Radiologe       Date:  2018-09       Impact factor: 0.635

5.  Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance.

Authors:  Hicham T Abada; Marc R Sapoval; Jean-François Paul; Viviane de Maertelaer; Elie Mousseaux; Jean-Claude Gaux
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

6.  Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR).

Authors:  Roberto Iezzi; M Santoro; R Dattesi; F Pirro; M Nestola; F Spigonardo; A R Cotroneo; L Bonomo
Journal:  Insights Imaging       Date:  2012-06-12

7.  Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm.

Authors:  Zarina Abdul Aziz; Purushotham R Naidu; Jagadish Prasad; Arjun Kalyanpur
Journal:  J Cardiovasc Dis Res       Date:  2010-07

8.  A mobile minimally invasive interventional shelter: a new answer to on-spot emergency treatment of large arterial injuries?

Authors:  Ming Liang; Jingjing Rong; Jingyang Sun; Tianming Yao; Fengqi Xuan; Lijun Zhao; Fei Li; Xiaozeng Wang; Yaling Han
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-09-04       Impact factor: 2.953

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.