OBJECTIVE: The purpose of this study was to define changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm.
METHODS: A total of 154 consecutive patients who underwent endovascular repair of abdominal aortic aneurysm with the Medtronic AneuRx stent graft at Stanford University Hospital were evaluated. During a mean follow-up period of 15.8 +/- 11.3 months, serial computerized measurements of aneurysm volume and orthogonal maximal diameter were performed on helical computed tomographic scan data sets and maximal transverse diameter was measured manually from transverse computed tomographic images. Aortoiliac length (renal to hypogastric artery origin) was measured along the median luminal centerline and along the straight line.
RESULTS: Aneurysm volume increased immediately after endovascular repair (from 180.2 +/- 69.9 mL to 187.9 +/- 71.6 mL; P <.001), but orthogonal and transverse diameter and aortoiliac length did not change significantly. During the follow-up period, mean volume decreased to 171.9 +/- 70.2 mL (P <.05) and straight-line and centerline aortoiliac length remained unchanged from preoperative values. Overall, volume decreased at a rate of 1.7 +/- 5.9 mL/mo (P <.001). During periods without endoleak, the rate of decrease was 3.2 +/- 5.5 mL/mo (P <.001), and during periods with endoleak, aneurysm volume increased at a rate of 2.0 +/- 5.3 mL/mo (P <.005), without a difference between types of endoleak. Predictive values for the presence of endoleak were similar for transverse and orthogonal diameter and volume. Logistic regression analysis showed volume to be most closely associated with the presence of endoleak.
CONCLUSION: Aneurysm volume increases immediately after endovascular repair. After repair, aneurysm volume gradually decreases and aortoiliac length remains unchanged. Changes in volume parallel changes in maximal aneurysm diameter, and their association with the presence of an endoleak does not appear to be appreciably stronger.

Entities:  

Mesh:

Year:  2002        PMID: 12170211     DOI: 10.1067/mva.2002.126085

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

1.  Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair.

Authors:  Vitaliano Buffa; Antonio Solazzo; Valeria D'Auria; Alessandra Del Prete; Andrea Vallone; Monica Luzietti; Manuela Madau; Roberto Grassi; Vittorio Miele
Journal:  Radiol Med       Date:  2014-07-02       Impact factor: 3.469

Review 2.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

3.  Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance.

Authors:  Hicham T Abada; Marc R Sapoval; Jean-François Paul; Viviane de Maertelaer; Elie Mousseaux; Jean-Claude Gaux
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

4.  Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR).

Authors:  Roberto Iezzi; M Santoro; R Dattesi; F Pirro; M Nestola; F Spigonardo; A R Cotroneo; L Bonomo
Journal:  Insights Imaging       Date:  2012-06-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.