Literature DB >> 12814929

Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT.

I Zammit-Maempel1, C L Chadwick, S P Willis.   

Abstract

CT has become an established examination in the evaluation of the paranasal sinuses. Until recently this was achieved by the direct coronal technique on conventional and single slice helical scanners. With the advent of multislice technology, thin slice axial CT with excellent coronal and sagittal reconstructions is now the norm. We describe a study designed to evaluate the radiation dose to the lens of the eye and thyroid gland in the axial and coronal planes on a Siemens Volume Zoom quad slice scanner at 140 kV and effective mAs of 100 using 1 mm collimation. Thermoluminescent dosimeters were placed on the eyelid and thyroid gland of 29 patients scanned axially in the supine position and a further 28 patients scanned coronally in the prone position with gantry tilt. The results show mean doses of 35.1 mGy (lens) and 2.9 mGy (thyroid gland) in the coronal plane compared with 24.5 mGy (lens) and 1.4 mGy (thyroid gland) in the axial plane. Results obtained from a head phantom and from using the ImPACT CT dose calculator were comparable. The kV and mAs were then reduced to 120 and 40, respectively, and the axial study repeated using the head phantom and predicted doses using the ImPACT CT dose calculator. The low dose scanning technique revealed a lens dose of 9.2 mGy and thyroid dose of 0.4 mGy. The eye dose on a multislice scanner is still substantially less than the threshold dose of 0.5-2 Gy for detectable lens opacities. These results indicate that, in addition to the established perceived advantages of multislice axial sinus CT, i.e. patient comfort, no artefact from dental amalgam and reproducible true coronal images, should be included a decreased radiation dose to both the eye lens and thyroid gland compared with direct coronal scanning.

Entities:  

Mesh:

Year:  2003        PMID: 12814929     DOI: 10.1259/bjr/82798696

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  14 in total

1.  Image quality and radiation exposure in 320-row temporal bone computed tomography.

Authors:  H C Bauknecht; E Siebert; A Dannenberg; G Bohner; C Jach; S Diekmann; C Scheurig; R Klingebiel
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

2.  Evaluation of reconstructed orbital wall fractures: high-resolution MRI using a microscopy surface coil versus 16-slice MSCT.

Authors:  E Wiener; A Kolk; A Neff; M Settles; E Rummeny
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

3.  Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Authors:  Abeer A Almashraqi; Eman A Ahmed; Nashwa S Mohamed; Imad H Barngkgei; Nader A Elsherbini; Esam S Halboub
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

4.  Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner.

Authors:  Masanao Kobayashi; Kichiro Koshida; Shoichi Suzuki; Kazuhiro Katada
Journal:  Radiol Phys Technol       Date:  2012-03-04

5.  Orbital fracture clinical decision rule development: burden of disease and use of a mandatory electronic survey instrument.

Authors:  Kabir Yadav; Ethan Cowan; Stephen Wall; Paul Gennis
Journal:  Acad Emerg Med       Date:  2011-02-25       Impact factor: 3.451

6.  Radiation exposure from CT in early childhood: a French large-scale multicentre study.

Authors:  M-O Bernier; J-L Rehel; H J Brisse; X Wu-Zhou; S Caer-Lorho; S Jacob; J F Chateil; B Aubert; D Laurier
Journal:  Br J Radiol       Date:  2012-01       Impact factor: 3.039

Review 7.  "Black bone" MRI: a potential alternative to CT when imaging the head and neck: report of eight clinical cases and review of the Oxford experience.

Authors:  K A Eley; S R Watt-Smith; S J Golding
Journal:  Br J Radiol       Date:  2012-11       Impact factor: 3.039

8.  Imaging in orbital trauma.

Authors:  Ken Y Lin; Philip Ngai; Julio C Echegoyen; Jeremiah P Tao
Journal:  Saudi J Ophthalmol       Date:  2012-10

9.  [Update: catheter-based balloon dilatation of the sinuses without fluoroscopy. Dilation technique with an illumination system].

Authors:  D Brehmer
Journal:  HNO       Date:  2008-08       Impact factor: 1.284

10.  Assessment of the Diagnostic Accuracy of Limited CT Scan of Paranasal Sinuses in the Identification of Sinusitis.

Authors:  Vahid Noorian; Arya Motaghi
Journal:  Iran Red Crescent Med J       Date:  2012-11-15       Impact factor: 0.611

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.