Literature DB >> 12803293

Systematic characterisation of silicon-embedded accelerometers for mechanomyography.

J Silva1, T Chau, S Naumann, W Heim.   

Abstract

Silicon soft suction sockets (roll-on sleeves) currently used in passive prostheses for below-elbow amputees could also be used in externally powered prostheses, enhancing their functionality and comfort. However, as it is extremely difficult to hold currently used electromyography (EMG) sensors in place reliably within a silicon socket, an alternative measurement of muscular activity as the control input is necessary. Mechanomyography (MMG) is the epidermal measurement of the low-frequency vibrations produced by a contracting muscle. MMG sensors do not have to be in direct contact with the skin. Moreover, the embedding of sensors in the roll-on sleeve may also solve attachment issues, making sensor placement flexible. Therefore the objective was to determine the feasibility of recording MMG signals using silicon-embedded, micro-machined accelerometers. Fifteen embedded accelerometers were excited with predefined vibration patterns. The signal-to-noise ratio (SNR) and frequency response of each sample were measured and compared with those of non-embedded accelerometers. The SNR of embedded samples (approximately equal to 19 dB) was significantly higher than that of non-embedded samples (approximately equal to 12 dB), owing to the considerable mechanical damping effect of the silicon in the 300-900 Hz bandwidth (p=0.0028). This has implications for the application of silicon-embedded accelerometers for externally powered prosthesis control.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12803293     DOI: 10.1007/bf02348433

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  10 in total

1.  Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration.

Authors:  M Ouamer; M Boiteux; M Petitjean; L Travens; A Salès
Journal:  J Biomech       Date:  1999-12       Impact factor: 2.712

2.  Silicone roll-on suspension for upper limb prostheses: users' views.

Authors:  T A Gaber; C M Gardner; S G Kirker
Journal:  Prosthet Orthot Int       Date:  2001-08       Impact factor: 1.895

3.  A comparative study of simultaneous vibromyography and electromyography with active human quadriceps.

Authors:  Y T Zhang; C B Frank; R M Rangayyan; G D Bell
Journal:  IEEE Trans Biomed Eng       Date:  1992-10       Impact factor: 4.538

4.  Acoustic myography as an indicator of force during sustained contractions of a small hand muscle.

Authors:  M S Goldenberg; H J Yack; F J Cerny; H W Burton
Journal:  J Appl Physiol (1985)       Date:  1991-01

5.  MMG measurement: a high-sensitivity microphone-based sensor for clinical use.

Authors:  A Courteville; T Gharbi; J Y Cornu
Journal:  IEEE Trans Biomed Eng       Date:  1998-02       Impact factor: 4.538

6.  Surface mechanomyogram reflects muscle fibres twitches summation.

Authors:  C Orizio; D Liberati; C Locatelli; D De Grandis; A Veicsteinas
Journal:  J Biomech       Date:  1996-04       Impact factor: 2.712

7.  Spectral analysis of muscular sound during isometric contraction of biceps brachii.

Authors:  C Orizio; R Perini; B Diemont; M Maranzana Figini; A Veicsteinas
Journal:  J Appl Physiol (1985)       Date:  1990-02

8.  Acoustic myography as a control signal for an externally powered prosthesis.

Authors:  D T Barry; J A Leonard; A J Gitter; R D Ball
Journal:  Arch Phys Med Rehabil       Date:  1986-04       Impact factor: 3.966

Review 9.  Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies.

Authors:  C Orizio
Journal:  Crit Rev Biomed Eng       Date:  1993

10.  Mechanical behaviour of condenser microphone in mechanomyography.

Authors:  M Watakabe; K Mita; K Akataki; Y Itoh
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

  10 in total
  1 in total

1.  Validation of an accelerometer for determination of muscle belly radial displacement.

Authors:  T Zagar; D Krizaj
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.