Literature DB >> 9473837

MMG measurement: a high-sensitivity microphone-based sensor for clinical use.

A Courteville1, T Gharbi, J Y Cornu.   

Abstract

High-sensitivity human muscle-vibration measurement (MMG) sensor adapted to clinical use is presented. The muscle vibration phenomenon is modeled and investigated to optimize the measurement technique. The sensor uses an acoustic impedance adaptation technique to convert the skin surface vibration in terms of acoustic pressure, which is sensed by a microphone. The device is calibrated and gives the real amplitude of the vibration. It is also well fitted to measure other physiological vibrations in the 2 Hz-1 KHz range.

Entities:  

Mesh:

Year:  1998        PMID: 9473837     DOI: 10.1109/10.661262

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Surface myomechanical responses recorded on a scanner galvanometer.

Authors:  D Rafolt; E Gallasch
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

2.  Surface electromyography and mechanomyography recording: a new differential composite probe.

Authors:  B Gregori; E Galié; N Accornero
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

3.  Systematic characterisation of silicon-embedded accelerometers for mechanomyography.

Authors:  J Silva; T Chau; S Naumann; W Heim
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

4.  Mechanical behaviour of condenser microphone in mechanomyography.

Authors:  M Watakabe; K Mita; K Akataki; Y Itoh
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

Review 5.  A review of non-invasive techniques to detect and predict localised muscle fatigue.

Authors:  Mohamed R Al-Mulla; Francisco Sepulveda; Martin Colley
Journal:  Sensors (Basel)       Date:  2011-03-24       Impact factor: 3.576

6.  Mechanomyographic parameter extraction methods: an appraisal for clinical applications.

Authors:  Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M Zuniga; Nazirah Hasnan; Ahmad Khairi Abdul Wahab
Journal:  Sensors (Basel)       Date:  2014-12-03       Impact factor: 3.576

7.  Implementation of Hand Gesture Recognition Device Applicable to Smart Watch Based on Flexible Epidermal Tactile Sensor Array.

Authors:  Sung-Woo Byun; Seok-Pil Lee
Journal:  Micromachines (Basel)       Date:  2019-10-12       Impact factor: 2.891

Review 8.  Intention Detection Strategies for Robotic Upper-Limb Orthoses: A Scoping Review Considering Usability, Daily Life Application, and User Evaluation.

Authors:  Jessica Gantenbein; Jan Dittli; Jan Thomas Meyer; Roger Gassert; Olivier Lambercy
Journal:  Front Neurorobot       Date:  2022-02-21       Impact factor: 2.650

Review 9.  Control Methods for Transradial Prostheses Based on Remnant Muscle Activity and Its Relationship with Proprioceptive Feedback.

Authors:  Stefan Grushko; Tomáš Spurný; Martin Černý
Journal:  Sensors (Basel)       Date:  2020-08-28       Impact factor: 3.576

  9 in total