A comparative study of simultaneous vibromyography and electromyography with active human quadriceps.

Y T Zhang1, C B Frank, R M Rangayyan, G D Bell.   

Abstract

Vibromyographic (VMG) signals, which are low-frequency vibration signals generated during muscle contraction, were studied in comparison with electromyographic (EMG) signals recorded simultaneously during isometric contraction of the human quadriceps muscles. The comparison was accomplished by evaluating the averaged root mean squared (rms) value, mean frequency (MF), and peak frequency (PF) of the VMG and EMG signals for four muscle contraction levels at joint angles of 30 degrees, 60 degrees, and 90 degrees. The four contraction levels, namely 20, 40, 60, and 80% of maximum voluntary contraction (MVC), were estimated and controlled by the torque readings of a Cybex II dynamometer. It was found that the VMG and EMG under the same conditions on the same muscle group are in general equally sensitive to the levels of muscle contraction. Results show that the rms value of the VMG signal increases linearly, in a manner similar to the EMG rms/%MVC relationship, with increasing muscle contraction levels. Furthermore, the study indicates that the averaged MF (6-24 Hz) and PF (9-19 Hz) of the VMG signals are much lower than the MF (75-109 Hz) and PF (40-80 Hz) of the EMG signals. The slopes of MF/%MVC curves for the VMG and EMG are approximately the same for 60 degrees and 90 degrees joint angles (approximately 3.1 Hz per 20% MVC for VMG and approximately 2.6 Hz per 20% MVC for EMG).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1452170     DOI: 10.1109/10.161336

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  12 in total

1.  Technical aspects of mechnomyography recording with piezoelectric contact sensor.

Authors:  M Watakabe; Y Itoh; K Mita; K Akataki
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Influence of estimators of spectral density on the analysis of electromyographic and vibromyographic signals.

Authors:  M A Mañanas; R Jané; J A Fiz; J Morera; P Caminal
Journal:  Med Biol Eng Comput       Date:  2002-01       Impact factor: 2.602

3.  Mechanomyographic responses during voluntary ramp contractions of the human first dorsal interosseous muscle.

Authors:  Kumi Akataki; Katsumi Mita; Makoto Watakabe; Kunihiko Itoh
Journal:  Eur J Appl Physiol       Date:  2003-04-24       Impact factor: 3.078

4.  Systematic characterisation of silicon-embedded accelerometers for mechanomyography.

Authors:  J Silva; T Chau; S Naumann; W Heim
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

5.  Mechanomyographic and electromyographic time and frequency domain responses during submaximal to maximal isokinetic muscle actions of the biceps brachii.

Authors:  Travis W Beck; Terry J Housh; Glen O Johnson; Joseph P Weir; Joel T Cramer; Jared W Coburn; Moh H Malek
Journal:  Eur J Appl Physiol       Date:  2004-04-23       Impact factor: 3.078

6.  Detecting subtle yet fast skeletal muscle contractions with ultrasoft and durable graphene-based cellular materials.

Authors:  Zijun He; Zheng Qi; Huichao Liu; Kangyan Wang; Leslie Roberts; Jefferson Z Liu; Yilun Liu; Stephen J Wang; Mark J Cook; George P Simon; Ling Qiu; Dan Li
Journal:  Natl Sci Rev       Date:  2021-10-05       Impact factor: 23.178

7.  Time and frequency domain analysis of electromyogram and sound myogram in the elderly.

Authors:  F Esposito; D Malgrati; A Veicsteinas; C Orizio
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

8.  Chronic hypobaric hypoxia does not affect electro-mechanical muscle activities during sustained maximal isometric contractions.

Authors:  Fabio Esposito; Claudio Orizio; Giovanni Parrinello; Arsenio Veicsteinas
Journal:  Eur J Appl Physiol       Date:  2003-08-22       Impact factor: 3.078

9.  Mechanomyographic parameter extraction methods: an appraisal for clinical applications.

Authors:  Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M Zuniga; Nazirah Hasnan; Ahmad Khairi Abdul Wahab
Journal:  Sensors (Basel)       Date:  2014-12-03       Impact factor: 3.576

10.  Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

Authors:  M Watakabe; K Mita; K Akataki; K Ito
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.