Literature DB >> 8964777

Surface mechanomyogram reflects muscle fibres twitches summation.

C Orizio1, D Liberati, C Locatelli, D De Grandis, A Veicsteinas.   

Abstract

The aim of this work is to define the pattern of summation of the muscle fibre twitches in the surface mechanomyogram (MMG) generation process. For this purpose, two groups of muscle fibres of the extensor digitorum communis (EDC) were stimulated using needle electrodes. To these two artificial (because made by different muscle fibre types) motor units (MU1 and MU2), we administered: (a) separate stimulations: 3 and 9 Hz (MU1), 8 and 20 Hz (MU2) for 5 s; (b) simultaneous stimulation: 3 Hz (MU1) + 8 Hz (MU2); 9 Hz (MU1) + 20 Hz (MU2) for 5 s. The mechanomyograms, recorded during separate stimulation of MU1 and MU2, were linearly summated for the generation of a mechanomyographic signal to be compared with the one detected during (b) stimulation procedure. The bispectrum and the bicoherence of the generated MMG (MMGg) and of the MMG recorded during simultaneous (MMGs) stimulation were calculated for the detection of the quadratic non-linearity in the system responses. It was found that the MMGg and MMGs presented difference in the bispectrum and bicoherence index only when the 9-20 Hz stimulation pair was considered In conclusion, our data indicate that the MMG derives from the summation of the active muscle fibres twitches and that the latter is linear only for very low firing rates. This is to be carefully considered when studies on MMG modelling will be undertaken.

Entities:  

Mesh:

Year:  1996        PMID: 8964777     DOI: 10.1016/0021-9290(95)00063-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  28 in total

1.  Technical aspects of mechnomyography recording with piezoelectric contact sensor.

Authors:  M Watakabe; Y Itoh; K Mita; K Akataki
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Systematic characterisation of silicon-embedded accelerometers for mechanomyography.

Authors:  J Silva; T Chau; S Naumann; W Heim
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

3.  Mechanomyographic responses in human biceps brachii and soleus during sustained isometric contraction.

Authors:  Tetsuya Kimura; Taku Hamada; Takeo Watanabe; Akifumi Maeda; Tomomichi Oya; Toshio Moritani
Journal:  Eur J Appl Physiol       Date:  2004-05-28       Impact factor: 3.078

4.  Non-invasive assessment of single motor unit mechanomyographic response and twitch force by spike-triggered averaging.

Authors:  C Cescon; M Gazzoni; M Gobbo; C Orizio; D Farina
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

5.  Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles.

Authors:  C Cescon; D Farina; M Gobbo; R Merletti; C Orizio
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

6.  Validation of an accelerometer for determination of muscle belly radial displacement.

Authors:  T Zagar; D Krizaj
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

7.  Muscle tissue oxygenation, pressure, electrical, and mechanical responses during dynamic and static voluntary contractions.

Authors:  Pernille Vedsted; Anne Katrine Blangsted; Karen Søgaard; Claudio Orizio; Gisela Sjøgaard
Journal:  Eur J Appl Physiol       Date:  2004-10-05       Impact factor: 3.078

8.  Surface EMG and mechanomyogram disclose isokinetic training effects on quadriceps muscle in elderly people.

Authors:  Fabio Esposito; Emiliano Cè; Massimiliano Gobbo; Arsenio Veicsteinas; Claudio Orizio
Journal:  Eur J Appl Physiol       Date:  2005-06-08       Impact factor: 3.078

9.  Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions.

Authors:  Pascal Madeleine; Hong-You Ge; Anna Jaskólska; Dario Farina; Artur Jaskólski; Lars Arendt-Nielsen
Journal:  Med Biol Eng Comput       Date:  2006-03-22       Impact factor: 2.602

10.  Effects of age and stimulus on submental mechanomyography signals during swallowing.

Authors:  Joon Lee; Tom Chau; Catriona M Steele
Journal:  Dysphagia       Date:  2009-01-14       Impact factor: 3.438

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.