Mechanical behaviour of condenser microphone in mechanomyography.

M Watakabe1, K Mita, K Akataki, Y Itoh.   

Abstract

Condenser microphones (MIC) have been widely used in mechanomyography, together with accelerometers and piezoelectric contact sensors. The aim of the present investigation was to clarify the mechanical variable (acceleration, velocity or displacement) indicated by the signal from a MIC transducer using a mechanical sinusoidal vibration system. In addition, the mechanomyogram (MMG) was recorded simultaneously with a MIC transducer and accelerometer (ACC) during voluntary contractions to confirm the mechanical variable reflected by the actual MMG and to examine the influence of motion artifact on the MMG. To measure the displacement-frequency response, mechanical sinusoidal vibrations of 3 to 300 Hz were applied to the MIC transducer with different sizes of air chambers (5, 10, 15 and 20 mm in diameter and 15, 20 or 25 mm long). The MIC transducer showed a linear relationship between the output amplitude and the vibration displacement, however, its frequency response declined with decreasing diameter and decreasing length of the air chamber. In fact, the cut-off frequency (-3dB) of the MIC transducer with the 5-mm-diameter chamber was 10, 8 and 4 Hz for the length 15, 20 and 25 mm, respectively. The air chamber with at least a diameter of 10 mm and a length of 15 mm is recommended for the MIC transducer. The sensitivity of this MIC transducer arrangement was 92 mV microm(-1) when excited at 100 Hz. During voluntary contraction, the amplitude spectral density function of the MMG from the MIC transducer resembled that of the double integral of the ACC transducer signal. The angle of the MIC transducer was delayed by 180 degrees in relation to the ACC transducer signal. The sensitivity of the MIC transducer was reduced to one-third because of the peculiar volume change of air chamber when the MMG was detected on the surface of the skin. In addition, the MIC transducer was contaminated by a smaller motion artifact than that from the ACC transducer. The maximal peak amplitude of the MIC and ACC transducer signal with the motion artifact was 7.7 and 12.3 times as much as the RMS amplitude of each signal without the motion artifact, respectively. These findings suggest that the MIC transducer acts as a displacement meter in the MMG. The MIC transducer seems to be a possible candidate for recording the MMG during dynamic muscle contractions as well as during sustained contractions.

Entities:  

Mesh:

Year:  2001        PMID: 11361247     DOI: 10.1007/BF02344804

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  28 in total

1.  Relationship between mechanomyogram and force during voluntary contractions reinvestigated using spectral decomposition.

Authors:  K Akataki; K Mita; Y Itoh
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1999-08

2.  Muscle sounds from evoked twitches in the hand.

Authors:  D T Barry
Journal:  Arch Phys Med Rehabil       Date:  1991-07       Impact factor: 3.966

3.  The sounds from single motor units in a contracting muscle.

Authors:  G Gordon; A H Holbourn
Journal:  J Physiol       Date:  1948-09-30       Impact factor: 5.182

4.  Relationship between mechanomyogram signals and changes in force of human forefinger flexor muscles during voluntary contraction.

Authors:  J Celichowski; K Grottel; E Bichler
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1998-09

5.  MMG measurement: a high-sensitivity microphone-based sensor for clinical use.

Authors:  A Courteville; T Gharbi; J Y Cornu
Journal:  IEEE Trans Biomed Eng       Date:  1998-02       Impact factor: 4.538

6.  Mechanomyography of the human quadriceps muscle during incremental cycle ergometry.

Authors:  M Shinohara; M Kouzaki; T Yoshihisa; T Fukunaga
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1997

7.  Mechanomyographic responses to concentric isokinetic muscle contractions.

Authors:  T K Evetovich; T J Housh; J R Stout; G O Johnson; D B Smith; K T Ebersole
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1997

8.  Effect of acclimatization to high altitude (5,050 m) on motor unit activation pattern and muscle performance.

Authors:  C Orizio; F Esposito; A Veicsteinas
Journal:  J Appl Physiol (1985)       Date:  1994-12

9.  Muscle fatigue measured with evoked muscle vibrations.

Authors:  D T Barry; T Hill; D Im
Journal:  Muscle Nerve       Date:  1992-03       Impact factor: 3.217

10.  Acoustic myography for investigating human skeletal muscle fatigue.

Authors:  M J Stokes; P A Dalton
Journal:  J Appl Physiol (1985)       Date:  1991-10
View more
  19 in total

1.  Surface myomechanical responses recorded on a scanner galvanometer.

Authors:  D Rafolt; E Gallasch
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

2.  Surface electromyography and mechanomyography recording: a new differential composite probe.

Authors:  B Gregori; E Galié; N Accornero
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

3.  Systematic characterisation of silicon-embedded accelerometers for mechanomyography.

Authors:  J Silva; T Chau; S Naumann; W Heim
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

4.  Validation of an accelerometer for determination of muscle belly radial displacement.

Authors:  T Zagar; D Krizaj
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

5.  Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions.

Authors:  Pascal Madeleine; Hong-You Ge; Anna Jaskólska; Dario Farina; Artur Jaskólski; Lars Arendt-Nielsen
Journal:  Med Biol Eng Comput       Date:  2006-03-22       Impact factor: 2.602

6.  Mechanomyographic responses in quadriceps muscles during fatigue by continuous cycle exercise.

Authors:  Tetsuya Kimura; Mami Fujibayashi; Seitaro Tanaka; Toshio Moritani
Journal:  Eur J Appl Physiol       Date:  2008-07-10       Impact factor: 3.078

7.  System identification of evoked mechanomyogram from abductor pollicis brevis muscle in isometric contraction.

Authors:  Takanori Uchiyama; Hiroaki Sakai
Journal:  Med Biol Eng Comput       Date:  2013-08-11       Impact factor: 2.602

8.  Comparison of displacement and acceleration transducers for the characterization of mechanics of muscle and subcutaneous tissues by system identification of a mechanomyogram.

Authors:  Takanori Uchiyama; Keita Shinohara
Journal:  Med Biol Eng Comput       Date:  2012-11-03       Impact factor: 2.602

9.  A new layered sensor for simultaneous measurement of EMG, MMG and oxygen consumption at the same position.

Authors:  Akira Kimoto; Yuji Yamada
Journal:  Med Biol Eng Comput       Date:  2014-10-10       Impact factor: 2.602

10.  The design and testing of a novel mechanomyogram-driven switch controlled by small eyebrow movements.

Authors:  Natasha Alves; Tom Chau
Journal:  J Neuroeng Rehabil       Date:  2010-05-21       Impact factor: 4.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.