Literature DB >> 12750455

Subtle lung nodules: influence of local anatomic variations on detection.

Ehsan Samei1, Michael J Flynn, Edward Peterson, William R Eyler.   

Abstract

PURPOSE: To assess the influence of local anatomic noise on the detection of subtle lung nodules depicted on chest radiographs.
MATERIALS AND METHODS: Six 8 x 8-cm lung regions were extracted from digital chest radiographs obtained in healthy subjects. Simulated nodules emulating the radiographic characteristics of subtle tissue-equivalent lesions 3.2-6.4 mm in diameter (equivalent to 0.1-0.4 mm in contrast-diameter product [CD]) were added to the images. On multiple renditions of each image, nodules were inserted at slightly different locations within 6 mm of the center; this process allowed different local background patterns to overlie the nodules. An observer detection study involving 15 experienced radiologists was performed. The authors performed analysis of variance and pairwise t test analyses to determine variations in nodule detectability related to nodule location and size on each image.
RESULTS: Results indicated a strong correlation between nodule size and observer detection score and significant variation in nodule detectability as a function of location. Changes in nodule position caused observer score variations that were equivalent to the variation caused by an up to 185% change in nodule CD (78% average over all six images), an up to 68% change in diameter (32% average), and an up to 28% change in area under the receiver operating characteristic curve (Az) (14% average).
CONCLUSION: Local anatomic variations surrounding and overlying a subtle lung nodule on a chest radiograph that are created by the projection of anatomic features in the thorax, such as ribs and pulmonary vessels, can greatly influence the detection of nodules, altering the Az by as much as 28%.

Entities:  

Mesh:

Year:  2003        PMID: 12750455     DOI: 10.1148/radiol.2273020509

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  11 in total

1.  Dose reduction and image quality in CT angiography for cerebral aneurysm with various tube potentials and current settings.

Authors:  K Imai; M Ikeda; C Kawaura; T Aoyama; Y Enchi; M Yamauchi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

2.  Preliminary evaluation of biplane correlation (BCI) stereographic imaging for lung nodule detection.

Authors:  Sarah J Boyce; H Page McAdams; Carl E Ravin; Edward F Patz; Lacey Washington; Santiago Martinez; Lynne Koweek; Ehsan Samei
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

3.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

4.  Toluidine blue color perception in identification of oral mucosal lesions.

Authors:  Pelin Güneri; Joel B Epstein; Selin Ergün; Hayal Boyacioğlu
Journal:  Clin Oral Investig       Date:  2010-03-25       Impact factor: 3.573

5.  Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

Authors:  Juergen Biederer; Tobias Gottwald; Hendrik Bolte; Christian Riedel; Sandra Freitag; Richard Van Metter; Martin Heller
Journal:  Eur Radiol       Date:  2006-09-09       Impact factor: 5.315

6.  Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice.

Authors:  Zsolt Szucs-Farkas; Michael A Patak; Seyran Yuksel-Hatz; Thomas Ruder; Peter Vock
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

7.  Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis.

Authors:  Sara A Asplund; Åse A Johnsson; Jenny Vikgren; Angelica Svalkvist; Agneta Flinck; Marianne Boijsen; Valeria A Fisichella; Lars Gunnar Månsson; Magnus Båth
Journal:  Eur Radiol       Date:  2014-05-04       Impact factor: 5.315

8.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

Authors:  Grace J Gang; Junghoon Lee; J Webster Stayman; Daniel J Tward; W Zbijewski; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

9.  The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis.

Authors:  Devon J Godfrey; H Page McAdams; James T Dobbins
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  Chest tomosynthesis: technical principles and clinical update.

Authors:  James T Dobbins; H Page McAdams
Journal:  Eur J Radiol       Date:  2009-07-18       Impact factor: 3.528

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.