Effective doses in standard protocols for multi-slice CT scanning.

Mathias Cohnen1, LudgerG J W Poll, Claudia Puettmann, Klaus Ewen, Andreas Saleh, Ulrich Mödder.   

Abstract

The purpose of this study was to assess the radiation exposure of patients in several standard protocols in multi-slice CT (MSCT). Scanning protocols for neck, chest, abdomen, and spine were examined on a Somatom Plus 4 Volume Zoom MSCT (Siemens, Erlangen, Germany) with changing slice collimation (4x1, 4x2.5, and 4x5 mm), and pitch factors (1, 1.5, and 2). Effective doses were calculated from LiF-TLD measurements at several organ sites using an Alderson-Rando phantom and compared with calculations using the weighted CTDI. Effective dose for MSCT of the neck was 2.8 mSv. For different protocols for MSCT of the chest, 7.5-12.9 mSv were found. In abdominal MSCT protocols, effective dose varied between 12.4 and 16.1 mSv. The MSCT of the spine may lead to 12 mSv. An excellent correlation between the effective dose as determined by LiF-TLD and the calculated effective dose using the weighted CTDI could be demonstrated; however, a difference of up to 30% (mean 14.3%) was noted. Standard protocols for MSCT as measured in this study showed effective doses of up to16 mSv. Phantom measurement data show a good correlation to estimations using the weighted CTDI.

Entities:  

Mesh:

Year:  2002        PMID: 12695839     DOI: 10.1007/s00330-002-1614-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Management of patient dose and image noise in routine pediatric CT abdominal examinations.

Authors:  Francis R Verdun; D Lepori; Pascal Monnin; Jean-François Valley; Pierre Schnyder; F Gudinchet
Journal:  Eur Radiol       Date:  2004-01-13       Impact factor: 5.315

2.  Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study.

Authors:  G Brix; U Lechel; R Veit; R Truckenbrodt; G Stamm; E M Coppenrath; J Griebel; H-D Nagel
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

Review 3.  Multi-detector CT: head and neck imaging.

Authors:  Martin G Mack; Jörn O Balzer; Christopher Herzog; Thomas J Vogl
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 4.  Multislice CT: update on radiation and screening.

Authors:  Mannudeep K Kalra; Michael M Maher; Sanjay Saini
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

5.  Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

Authors:  Takashi Shirasaka; Yoshinori Funama; Mutsukazu Hayashi; Shinichi Awamoto; Masatoshi Kondo; Yasuhiko Nakamura; Masamitsu Hatakenaka; Hiroshi Honda
Journal:  Radiol Phys Technol       Date:  2011-10-15

6.  Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program.

Authors:  C Hohl; G Mühlenbruch; J E Wildberger; C Leidecker; C Süss; T Schmidt; R W Günther; A H Mahnken
Journal:  Eur Radiol       Date:  2006-02-03       Impact factor: 5.315

7.  Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose.

Authors:  B Wintersperger; T Jakobs; P Herzog; S Schaller; K Nikolaou; C Suess; C Weber; M Reiser; C Becker
Journal:  Eur Radiol       Date:  2004-12-21       Impact factor: 5.315

Review 8.  CT colonography: an update.

Authors:  Andrik J Aschoff; Andrea S Ernst; Hans-Juergen Brambs; Markus S Juchems
Journal:  Eur Radiol       Date:  2007-09-25       Impact factor: 5.315

9.  Evaluation of dose exposure in 64-slice CT colonography.

Authors:  O Luz; M Buchgeister; M Klabunde; T Trabold; A F Kopp; C D Claussen; M Heuschmid
Journal:  Eur Radiol       Date:  2007-02-07       Impact factor: 5.315

10.  Patient radiation exposure in uterine artery embolization of leiomyomata: calculation of organ doses and effective dose.

Authors:  S Vetter; F W Schultz; E-P Strecker; J Zoetelief
Journal:  Eur Radiol       Date:  2003-10-10       Impact factor: 5.315