Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

M Watakabe1, K Mita, K Akataki, K Ito.   

Abstract

The accelerometer is used for mechanomyogram (MMG) recordings of muscle contractions. Although the mechanical characteristics of other MMG transducers have been determined with reference to the accelerometer, mechanical aspects of the accelerometer itself, including the weight of the transducer, have not been verified. This study was designed to reinvestigate the mechanical variable of the MMG signal detected with an accelerometer, with reference to a laser distance sensor (LDS), and then to clarify the influence of the accelerometer weight on the MMG recording during muscle contractions. The study was performed during mechanical sinusoidal vibrations and during voluntary contractions of the quadriceps muscle. Maximum differences in the amplitude spectral density functions between the LDS signal and the double integral of the accelerometer signal were approximately 4 microm. The results verified that the MMG signal from the accelerometer accurately reflected the acceleration of body surface vibration. However, the MMG signal was gradually distorted when weight was added to the accelerometer: the addition of 4.0 g (total 6.0 g, including 2.0 g of accelerometer) substantially attenuated the MMG signal. The results suggest that the appropriate weight for the accelerometer should be less than 5.0 g for measurements of the quadriceps muscle and indicate that the transducer weight must be taken into account for accurate measurement of muscles of different sizes.

Entities:  

Mesh:

Year:  2003        PMID: 12691440     DOI: 10.1007/BF02344888

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  10 in total

1.  Technical aspects of mechnomyography recording with piezoelectric contact sensor.

Authors:  M Watakabe; Y Itoh; K Mita; K Akataki
Journal:  Med Biol Eng Comput       Date:  1998-09       Impact factor: 2.602

2.  Force and surface mechanomyogram frequency responses in cat gastrocnemius.

Authors:  C Orizio; R V Baratta; B H Zhou; M Solomonow; A Veicsteinas
Journal:  J Biomech       Date:  2000-04       Impact factor: 2.712

3.  Force and surface mechanomyogram relationship in cat gastrocnemius.

Authors:  C Orizio; R V Baratta; B H Zhou; M Solomonow; A Veicsteinas
Journal:  J Electromyogr Kinesiol       Date:  1999-04       Impact factor: 2.368

4.  A comparative study of simultaneous vibromyography and electromyography with active human quadriceps.

Authors:  Y T Zhang; C B Frank; R M Rangayyan; G D Bell
Journal:  IEEE Trans Biomed Eng       Date:  1992-10       Impact factor: 4.538

5.  Recording sound from human skeletal muscle: technical and physiological aspects.

Authors:  C F Bolton; A Parkes; T R Thompson; M R Clark; C J Sterne
Journal:  Muscle Nerve       Date:  1989-02       Impact factor: 3.217

Review 6.  Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies.

Authors:  C Orizio
Journal:  Crit Rev Biomed Eng       Date:  1993

7.  Technical aspects of acoustic myography (AMG) of human skeletal muscle: contact pressure and force/AMG relationships.

Authors:  T G Smith; M J Stokes
Journal:  J Neurosci Methods       Date:  1993-04       Impact factor: 2.390

8.  The recording of heart vibrations: a problem of vibration measurement on soft tissue.

Authors:  H Vermarien; E van Vollenhoven
Journal:  Med Biol Eng Comput       Date:  1984-03       Impact factor: 2.602

9.  Muscle fatigue measured with evoked muscle vibrations.

Authors:  D T Barry; T Hill; D Im
Journal:  Muscle Nerve       Date:  1992-03       Impact factor: 3.217

10.  Mechanical behaviour of condenser microphone in mechanomyography.

Authors:  M Watakabe; K Mita; K Akataki; Y Itoh
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

  10 in total
  7 in total

1.  Estimation of elbow flexion force during isometric muscle contraction from mechanomyography and electromyography.

Authors:  Wonkeun Youn; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2010-06-04       Impact factor: 2.602

2.  Validation of an accelerometer for determination of muscle belly radial displacement.

Authors:  T Zagar; D Krizaj
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

3.  Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions.

Authors:  Pascal Madeleine; Hong-You Ge; Anna Jaskólska; Dario Farina; Artur Jaskólski; Lars Arendt-Nielsen
Journal:  Med Biol Eng Comput       Date:  2006-03-22       Impact factor: 2.602

4.  A new layered sensor for simultaneous measurement of EMG, MMG and oxygen consumption at the same position.

Authors:  Akira Kimoto; Yuji Yamada
Journal:  Med Biol Eng Comput       Date:  2014-10-10       Impact factor: 2.602

5.  Mechanomyographic parameter extraction methods: an appraisal for clinical applications.

Authors:  Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M Zuniga; Nazirah Hasnan; Ahmad Khairi Abdul Wahab
Journal:  Sensors (Basel)       Date:  2014-12-03       Impact factor: 3.576

6.  Neck sensor-supported hyoid bone movement tracking during swallowing.

Authors:  Shitong Mao; Zhenwei Zhang; Yassin Khalifa; Cara Donohue; James L Coyle; Ervin Sejdic
Journal:  R Soc Open Sci       Date:  2019-07-10       Impact factor: 2.963

7.  Indices reflecting muscle contraction performance during exercise based on a combined electromyography and mechanomyography approach.

Authors:  Takaki Kawashima; Hisao Oka; Shinichi Fukuhara
Journal:  Sci Rep       Date:  2021-10-27       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.