A new layered sensor for simultaneous measurement of EMG, MMG and oxygen consumption at the same position.

Akira Kimoto1, Yuji Yamada.   

Abstract

A new layered sensor for simultaneous measurement of electromyography (EMG), mechanomyography (MMG) and oxygen consumption based on near-infrared spectroscopy (NIRS) at the same position of the muscle is presented. The proposed sensor is a layered structure of a thin stainless-steel electrode, a PVDF film with transparent electrodes and optical sensors. EMG, MMG and oxygen consumption based on NIRS are measured by the stainless-steel electrodes, PVDF film and optical sensors, respectively. Using the three types of data, muscular activity can be analyzed in more detail. Additionally, the proposed sensor system reduces the constraint of the sensors arranged on the skin in measurements at multiple points because three types of information, previously obtained with three types of general sensors, are detected by a pair of proposed sensors. In an experiment, simultaneous measurement of EMG, MMG and oxygen consumption via NIRS at the forearm was demonstrated using the proposed sensor under fluorescent light. The performance of the layered sensor was evaluated.

Entities:  

Mesh:

Year:  2014        PMID: 25300403     DOI: 10.1007/s11517-014-1208-0

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  20 in total

1.  Surface electromyography and mechanomyography recording: a new differential composite probe.

Authors:  B Gregori; E Galié; N Accornero
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

2.  Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles.

Authors:  C Cescon; D Farina; M Gobbo; R Merletti; C Orizio
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

3.  A new method to measure local oxygen consumption in human skeletal muscle during dynamic exercise using near-infrared spectroscopy.

Authors:  Tiziano Binzoni; Chris E Cooper; Anna L Wittekind; Ralph Beneke; Clare E Elwell; Dimitri Van De Ville; Terence S Leung
Journal:  Physiol Meas       Date:  2010-08-11       Impact factor: 2.833

4.  Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis.

Authors:  Didier Staudenmann; Idsart Kingma; Andreas Daffertshofer; Dick F Stegeman; Jaap H van Dieën
Journal:  IEEE Trans Biomed Eng       Date:  2006-04       Impact factor: 4.538

5.  Acoustic signals from frog skeletal muscle.

Authors:  D T Barry
Journal:  Biophys J       Date:  1987-05       Impact factor: 4.033

6.  Phonomyogram from single motor units during voluntary isometric contraction.

Authors:  M Petitjean; B Maton
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

7.  Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy.

Authors:  R A De Blasi; M Cope; C Elwell; F Safoue; M Ferrari
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993

8.  Electromyogram and kinematic analysis of lateral bending in idiopathic scoliosis patients.

Authors:  V Feipel; C E Aubin; O C Ciolofan; M Beauséjour; H Labelle; P A Mathieu
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

9.  Mechanical behaviour of condenser microphone in mechanomyography.

Authors:  M Watakabe; K Mita; K Akataki; Y Itoh
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

10.  Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

Authors:  M Watakabe; K Mita; K Akataki; K Ito
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

View more
  4 in total

1.  Segmenting Mechanomyography Measures of Muscle Activity Phases Using Inertial Data.

Authors:  Richard B Woodward; Maria J Stokes; Sandra J Shefelbine; Ravi Vaidyanathan
Journal:  Sci Rep       Date:  2019-04-03       Impact factor: 4.379

2.  A biosignal analysis for reducing prosthetic control durations: a proposed method using electromyographic and mechanomyographic control theory.

Authors:  Cory M Smith; Terry J Housh; Ethan C Hill; Joshua L Keller; Glen O Johnson; Richard J Schmidt
Journal:  J Musculoskelet Neuronal Interact       Date:  2019-06-01       Impact factor: 2.041

3.  Validation of Fabric-Based Thigh-Wearable EMG Sensors and Oximetry for Monitoring Quadriceps Activity during Strength and Endurance Exercises.

Authors:  Riccardo Di Giminiani; Marco Cardinale; Marco Ferrari; Valentina Quaresima
Journal:  Sensors (Basel)       Date:  2020-08-19       Impact factor: 3.576

Review 4.  Application of Modern Multi-Sensor Holter in Diagnosis and Treatment.

Authors:  Erik Vavrinsky; Jan Subjak; Martin Donoval; Alexandra Wagner; Tomas Zavodnik; Helena Svobodova
Journal:  Sensors (Basel)       Date:  2020-05-07       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.