Literature DB >> 8321016

Technical aspects of acoustic myography (AMG) of human skeletal muscle: contact pressure and force/AMG relationships.

T G Smith1, M J Stokes.   

Abstract

The effect of contact pressure on acoustic myographic (AMG) recordings was examined during voluntary isometric contractions of the human quadriceps muscle in 20 normal males. A piezoelectric disk for recording muscle sounds was placed over rectus femoris at approximately mid-thigh and secured with a rubber electromyography (EMG) strap. Contact pressure was monitored by a load cell placed between the AMG device and the strap. With the subject seated, force at different percentage levels of maximum voluntary contraction (MVC) were held for 5 s each. Both AMG and EMG recordings were full-wave rectified and integrated (IAMG and IEMG) and expressed as a percentage of activity at MVC. Two contraction series were performed with 2 different contact pressures. Pressure 1 (P1), of 180 Pa was applied in all subjects. A higher pressure of either 790 Pa (P2; in 5 subjects) or 1200 Pa (P3; in 15 subjects) was also applied. No significant changes in IAMG activity (P > 0.1) occurred between P1 and P2 but P3 produced increases in IAMG at all force levels (P < 0.05 at 10, 50 and 75% MVC). Both linear and non-linear relationships between force and IAMG were observed in different subjects but the relationship also varied with the 2 contact pressures within some subjects. The force/IEMG relationship was linear in all cases. These results provide quantitative evidence that contact pressure can influence the degree of IAMG activity if the pressure is high enough. The change in the force/IAMG relationship with pressure in some subjects suggests that the different relationships observed are not determined by physiological differences between subjects but rather by technical factors.

Entities:  

Mesh:

Year:  1993        PMID: 8321016     DOI: 10.1016/0165-0270(93)90024-l

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  9 in total

1.  Surface myomechanical responses recorded on a scanner galvanometer.

Authors:  D Rafolt; E Gallasch
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

2.  Surface electromyography and mechanomyography recording: a new differential composite probe.

Authors:  B Gregori; E Galié; N Accornero
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

3.  Vibromyographic recording from human muscles with known fibre composition differences.

Authors:  D Mealing; G Long; P W McCarthy
Journal:  Br J Sports Med       Date:  1996-03       Impact factor: 13.800

4.  Comparative study of a muscle stiffness sensor and electromyography and mechanomyography under fatigue conditions.

Authors:  Hyonyoung Han; Sungho Jo; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2015-03-10       Impact factor: 2.602

5.  Resting mechanomyography before and after resistance exercise.

Authors:  William P S McKay; Philip D Chilibeck; Brian L F Daku
Journal:  Eur J Appl Physiol       Date:  2007-10-02       Impact factor: 3.078

Review 6.  Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review.

Authors:  Travis W Beck; Terry J Housh; Joel T Cramer; Joseph P Weir; Glen O Johnson; Jared W Coburn; Moh H Malek; Michelle Mielke
Journal:  Biomed Eng Online       Date:  2005-12-19       Impact factor: 2.819

7.  Mechanomyographic parameter extraction methods: an appraisal for clinical applications.

Authors:  Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M Zuniga; Nazirah Hasnan; Ahmad Khairi Abdul Wahab
Journal:  Sensors (Basel)       Date:  2014-12-03       Impact factor: 3.576

8.  New advances in mechanomyography sensor technology and signal processing: Validity and intrarater reliability of recordings from muscle.

Authors:  Claire Meagher; Enrico Franco; Ruth Turk; Samuel Wilson; Nathan Steadman; Lauren McNicholas; Ravi Vaidyanathan; Jane Burridge; Maria Stokes
Journal:  J Rehabil Assist Technol Eng       Date:  2020-04-09

9.  Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions.

Authors:  M Watakabe; K Mita; K Akataki; K Ito
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.