Age and gender do not influence the ability to detect respiration by photoplethysmography.

Lena Nilsson1, Tomas Goscinski, Anders Johansson, Lars-Göran Lindberg, Sigga Kalman.   

Abstract

OBJECTIVE: The non-invasive technique photoplethysmography (PPG) can detect changes in blood volume and perfusion in a tissue. Respiration causes variations in the peripheral circulation, making it possible to monitor breaths using an optical sensor attached to the skin. The respiratory-synchronous part of the PPG signal (PPGr) has been used to monitor respiration during anaesthesia, and in postoperative and neonatal care. Studies addressing possible differences in PPGr signal characteristics depending on gender or age are lacking.
METHODS: We studied three groups of 16 healthy subjects each during normal breathing; young males, old males and young females, and calculated the concordance between PPGr, derived from a reflection mode PPG sensor on the forearm, and a reference CO(2 )signal. The concordance was quantified by using a squared coherence analysis. Time delay between the two signals was calculated. In this process, we compared three different methods for calculating time delay.
RESULTS: Coherence values >or=0.92 were seen for all three groups without any significant differences depending on age or gender (p = 0.67). Comparison between the three different methods for calculating time delay showed a correlation r = 0.93.
CONCLUSIONS: These results demonstrate clinically important information implying the possibility to register qualitative PPGr signals for respiration monitoring, regardless of age and gender.

Entities:  

Mesh:

Year:  2006        PMID: 17033878     DOI: 10.1007/s10877-006-9050-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  19 in total

1.  Photoplethysmography for simultaneous recording of heart and respiratory rates in newborn infants.

Authors:  E Olsson; H Ugnell; P A Oberg; G Sedin
Journal:  Acta Paediatr       Date:  2000-07       Impact factor: 2.299

2.  Influence of tidal volume and thoraco-abdominal separation on the respiratory induced variation of the photoplethysmogram.

Authors:  A Johansson; T Strömberg
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  Macrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal.

Authors:  L Nilsson; A Johansson; S Kalman
Journal:  Physiol Meas       Date:  2003-11       Impact factor: 2.833

Review 4.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

5.  Development of a compact home health monitor for telemedicine.

Authors:  Gilwon Yoon; Jong Yeon Lee; Kye Jin Jeon; Kun Kook Park; Hong Sig Kim
Journal:  Telemed J E Health       Date:  2005-12       Impact factor: 3.536

6.  Age affects proximal brachial artery stiffness; differential behavior within the length of the brachial artery?

Authors:  Niclas Bjarnegård; Asa Rydén Ahlgren; Thomas Sandgren; Björn Sonesson; Toste Länne
Journal:  Ultrasound Med Biol       Date:  2003-08       Impact factor: 2.998

7.  Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves.

Authors:  L Bernardi; A Radaelli; P L Solda; A J Coats; M Reeder; A Calciati; C S Garrard; P Sleight
Journal:  Clin Sci (Lond)       Date:  1996-05       Impact factor: 6.124

Review 8.  [Hypertension as a function of age].

Authors:  G F Gensini; F Corradi
Journal:  Ital Heart J       Date:  2000-06

9.  Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode.

Authors:  L Nilsson; A Johansson; S Kalman
Journal:  Acta Anaesthesiol Scand       Date:  2005-09       Impact factor: 2.105

10.  Experimental evaluation of two new sensors for respiratory rate monitoring.

Authors:  M Vegfors; H Ugnell; B Hök; P A Oberg; C Lennmarken
Journal:  Physiol Meas       Date:  1993-05       Impact factor: 2.833

View more
  1 in total

Review 1.  Sources of Inaccuracy in Photoplethysmography for Continuous Cardiovascular Monitoring.

Authors:  Jesse Fine; Kimberly L Branan; Andres J Rodriguez; Tananant Boonya-Ananta; Jessica C Ramella-Roman; Michael J McShane; Gerard L Coté
Journal:  Biosensors (Basel)       Date:  2021-04-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.