Evaluation of various models for respiratory inductance plethysmography calibration.

N O Strömberg1, G O Dahlbäck, P M Gustafsson.   

Abstract

We evaluated one nonlinear and two linear models of the ventilatory system while calibrating the respiratory inductance plethysmograph (RIP) against a pneumotachometer. A calibration method involving voluntary varying rib cage and abdominal contributions to tidal volume in a single body position was utilized. The influence on accuracy of the choice of respiratory phase during calibration was assessed. Both tidal and intratidal volumes were evaluated. Ten adults with no history of respiratory disorders went through RIP calibration and validation in the sitting and supine positions. A linear calibration model, relating lung volume changes from the start of inspiration or expiration to rib cage and abdominal excursions from initiation of respiratory motion, had the best accuracy. The choice of respiratory phase for calibration did not affect accuracy. RIP generally underestimated lung volume at the start of inspiration and overestimated lung volume at the end of inspiration. RIP was more accurate in the supine than the sitting position, probably because of limited spine flexion in the supine position.

Entities:  

Mesh:

Year:  1993        PMID: 8482659     DOI: 10.1152/jappl.1993.74.3.1206

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  10 in total

1.  Error analysis of a natural breathing calibration method for respiratory inductive plethysmography.

Authors:  N O Strömberg
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

2.  Influence of tidal volume and thoraco-abdominal separation on the respiratory induced variation of the photoplethysmogram.

Authors:  A Johansson; T Strömberg
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  A novel, non-invasive method of respiratory monitoring for use with stereotactic procedures.

Authors:  Daniel R Cleary; Ryan S Phillips; Michael Wallisch; Mary M Heinricher
Journal:  J Neurosci Methods       Date:  2012-07-04       Impact factor: 2.390

4.  Respiratory modulation of startle eye blink: a new approach to assess afferent signals from the respiratory system.

Authors:  André Schulz; Thomas M Schilling; Claus Vögele; Mauro F Larra; Hartmut Schächinger
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2016-10-10       Impact factor: 6.237

5.  The Accuracy of Respiratory Calibration Methods for Estimating Lung Volume During Speech Breathing: A Comparison of Four Methods Across Three Adult Cohorts.

Authors:  Victoria S McKenna; Jessica E Huber
Journal:  J Speech Lang Hear Res       Date:  2019-07-22       Impact factor: 2.297

6.  Improved regression models for ventilation estimation based on chest and abdomen movements.

Authors:  Shaopeng Liu; Robert Gao; Qingbo He; John Staudenmayer; Patty Freedson
Journal:  Physiol Meas       Date:  2012-01       Impact factor: 2.833

7.  Circadian affective, cardiopulmonary, and cortisol variability in depressed and nondepressed individuals at risk for cardiovascular disease.

Authors:  Ansgar Conrad; Frank H Wilhelm; Walton T Roth; David Spiegel; C Barr Taylor
Journal:  J Psychiatr Res       Date:  2007-09-19       Impact factor: 4.791

8.  Comparison of Respiratory Calibration Methods for the Estimation of Lung Volume in Children With and Without Neuromotor Disorders.

Authors:  Meghan Darling-White
Journal:  J Speech Lang Hear Res       Date:  2022-01-20       Impact factor: 2.674

9.  Reducing the airflow waveform distortions from breathing style and body position with improved calibration of respiratory effort belts.

Authors:  Tiina M Seppänen; Olli-Pekka Alho; Tapio Seppänen
Journal:  Biomed Eng Online       Date:  2013-09-28       Impact factor: 2.819

10.  End-expiratory lung volume remains stable during N2 MBW in healthy sleeping infants.

Authors:  Per M Gustafsson; Laszlo Kadar; Sanna Kjellberg; Lena Andersson; Anders Lindblad; Paul D Robinson
Journal:  Physiol Rep       Date:  2020-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.