Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzer.

Hisako Shibata1, Takahisa Yamane, Ryousuke Yamamura, Kensuke Ohta, Takayuki Takubo, Tomio Kamitani, Masayuki Hino.   

Abstract

The bone marrow aspiration test conventionally has been performed by visual methods, using a light microscope, because automatic blood cell analyzers cannot adequately capture erythroblasts and immature granulocytes (IGs) (Tatsumi et al.: Osaka City Med J 1988;34:135-146; Tatsumi et al.: Am J Clin Pathol 1986;86:50-54). With the development of the XE-2100 automatic blood cell analyzer (Sysmex Corporation, Kobe, Japan) in 1999, the classification of erythroblasts and IGs by means of flow cytometry (Zini et al.: Infus Ther Transfus Med 2001;28:277-279; Briggs et al.: Sysmex J Int 1999;9:113-119) became possible. In the present study we classified cells in 65 bone marrow aspiration specimens by the microscopic method and with the XE2100, and compared the results. A good correlation was found in the nucleated red blood cell (NRBC), white blood cell (WBC), and total nucleated cell (TNC) counts; the myeloid/erythroid ratio (M/E ratio); neutrophils, lymphocytes, eosinophils, and IGs in the immature myeloid information (IMI) channel; and the total cell count. These items can all be analyzed in about 54 sec with the XE2100, which is faster than with the microscopic method. Therefore, analysis of bone marrow aspiration specimens with this apparatus appears to be very useful for clinical screening as well as laboratory testing. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 12526017      PMCID: PMC6807842          DOI: 10.1002/jcla.10061

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  11 in total

1.  Artefactual elevation of the automated white cell count in the context of a bone marrow aspirate analysis.

Authors:  J F Lesesve; J J Goupil; V Latger; J Buisine; T Lecompte
Journal:  Clin Lab Haematol       Date:  2000-02

2.  The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology.

Authors:  K Ruzicka; M Veitl; R Thalhammer-Scherrer; I Schwarzinger
Journal:  Arch Pathol Lab Med       Date:  2001-03       Impact factor: 5.534

3.  Quantification of red blood cell fragmentation by automated haematology analyser XE-2100.

Authors:  M Jiang; K Saigo; S Kumagai; S Imoto; Y Kosaka; H Matsumoto; K Fujimoto
Journal:  Clin Lab Haematol       Date:  2001-06

4.  New quantitative parameters on a recently introduced automated blood cell counter--the XE 2100.

Authors:  C Briggs; P Harrison; D Grant; J Staves; S J MacHin
Journal:  Clin Lab Haematol       Date:  2000-12

5.  Possible automatic cell classification of bone marrow aspirate using the CELL-DYN 4000 automatic blood cell analyzer.

Authors:  Ryousuke Yamamura; Takahisa Yamane; Masayuki Hino; Kensuke Ohta; Hisako Shibata; Izumi Tsuda; Noriyuki Tatsumi
Journal:  J Clin Lab Anal       Date:  2002       Impact factor: 2.352

6.  Counting and differential of bone marrow cells by an electronic method.

Authors:  J Tatsumi; Y Tatsumi; N Tatsumi
Journal:  Am J Clin Pathol       Date:  1986-07       Impact factor: 2.493

7.  Histogram differential for bone marrow cells by an automated electronic conventional blood cell counting.

Authors:  N Tatsumi; Y Yokomatsu; K Kojima; K Setoguchi; T Im; I Tsuda
Journal:  Osaka City Med J       Date:  1988-10

8.  Automated enumeration of cellular composition in bone marrow aspirate with the CELL-DYN 4000 automated hematology analyzer.

Authors:  C Sakamoto; T Yamane; K Ohta; M Hino; I Tsuda; N Tatsumi
Journal:  Acta Haematol       Date:  1999       Impact factor: 2.195

9.  Correction of bone marrow nucleated cell counts for the presence of fat particles.

Authors:  S A Bentley; M A Taylor; D E Killian; S B Schoultz; L McLannan; C A Bishop; T C Shea; M E Brecher
Journal:  Am J Clin Pathol       Date:  1995-07       Impact factor: 2.493

10.  First basic performance evaluation of the XE-2100 haematology analyser.

Authors:  I Tsuda; M Hino; T Takubo; T Katagami; H Kubota; S Kawai; N Tatsumi
Journal:  J Autom Methods Manag Chem       Date:  1999
View more
  1 in total

1.  Reliable assessment of bone marrow and bone marrow concentrates using automated hematology analyzer.

Authors:  Venkata P Mantripragada; Nicolas S Piuzzi; Jaiben George; Wesley Bova; Mitchell Ng; Cynthia Boehm; George F Muschler
Journal:  Regen Med       Date:  2019-07-19       Impact factor: 3.806

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.