Literature DB >> 7611183

Correction of bone marrow nucleated cell counts for the presence of fat particles.

S A Bentley1, M A Taylor, D E Killian, S B Schoultz, L McLannan, C A Bishop, T C Shea, M E Brecher.   

Abstract

Although the use of bone marrow transplantation has increased greatly in recent years, the quality control procedures used in bone marrow processing laboratories remain less than ideal. Accurate marrow total nucleated cell (TNC) counts are essential for effective monitoring of bone marrow collection and processing. Aspirated marrow is variably contaminated by fat particles, resulting in overestimation of marrow TNC by automated analyzers. A recently-marketed hematological analyzer (Cobas-Helios; Roche Diagnostic Systems, Branchburg, NJ) offers the potential to correct marrow TNC counts for fat particles using available software. The authors investigated the accuracy of corrected TNC counts on 21 marrow samples, using a visual chamber count as the reference method. The correction methods studied were software correction, using the Cobas-Helios differential system, and replacement of the sample plasma with saline. Uncorrected automated marrow TNC counts (mean, 28.4 x 10(9)/L) were significantly higher than the visual reference counts (mean, 23.1 x 10(9)/L). Neither the mean corrected automated count (24.3 x 10(9)/L) nor the mean saline replaced count (24.6 x 10(9)/L) differed significantly from the mean visual reference count. For both the corrected automated and saline replaced counts, 20 of the 21 data points (95%) fell within a 95% confidence interval computed for the reference method. The authors conclude that both the corrected automated method, using the Cobas-Helios, and the saline replacement method are acceptable alternatives to the visual chamber count.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7611183     DOI: 10.1093/ajcp/104.1.60

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  3 in total

1.  Possible automatic cell classification of bone marrow aspirate using the CELL-DYN 4000 automatic blood cell analyzer.

Authors:  Ryousuke Yamamura; Takahisa Yamane; Masayuki Hino; Kensuke Ohta; Hisako Shibata; Izumi Tsuda; Noriyuki Tatsumi
Journal:  J Clin Lab Anal       Date:  2002       Impact factor: 2.352

2.  Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzer.

Authors:  Hisako Shibata; Takahisa Yamane; Ryousuke Yamamura; Kensuke Ohta; Takayuki Takubo; Tomio Kamitani; Masayuki Hino
Journal:  J Clin Lab Anal       Date:  2003       Impact factor: 2.352

3.  Characterization of the myelotoxicity of chloramphenicol succinate in the B6C3F1 mouse.

Authors:  John A Turton; Rajni Fagg; William R Sones; Thomas C Williams; C Michael Andrews
Journal:  Int J Exp Pathol       Date:  2006-04       Impact factor: 1.925

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.