Literature DB >> 11553057

Quantification of red blood cell fragmentation by automated haematology analyser XE-2100.

M Jiang1, K Saigo, S Kumagai, S Imoto, Y Kosaka, H Matsumoto, K Fujimoto.   

Abstract

The extent of red blood cell fragmentation in peripheral blood is useful for diagnosis and follow-up in many diseases, e.g. haemolytic uremic syndrome, transplantation-associated thrombotic microangiopathy (BMT-TMA). However, this quantification still relies on manual counting of fragmented red cells on blood smears. We have developed a quantification system by gating a fixed area of fragmented red blood cells (Gate 1) on an automated haematology analyser (XE-2100, Sysmex Co., Kobe, Japan). The fragmented red cell percentage (FRC%) calculated with this system, from 100 samples, was highly correlated with the manual count (r=0.902, P < 0.0001). Because microcytic anaemia specimens usually occupy a lower position on the XE-2100 scattergram, with microcytic cells overlapping Gate 1 and causing a spuriously high FRC% calculation, a supplementary gate (Gate 2) was added. Using the particle number in this gate as well as in Gate 1, a revised method for such samples was developed and its validity confirmed (revised FRC% correlated with a manual count for 10 subjects (P < 0.001). Because this gating system can be programmed on any XE-2100, it is likely to prove useful for accurate quantification of red blood cell fragmentation and for the monitoring of the development of BMT-TMA.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11553057     DOI: 10.1046/j.1365-2257.2001.00386.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  3 in total

1.  Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzer.

Authors:  Hisako Shibata; Takahisa Yamane; Ryousuke Yamamura; Kensuke Ohta; Takayuki Takubo; Tomio Kamitani; Masayuki Hino
Journal:  J Clin Lab Anal       Date:  2003       Impact factor: 2.352

2.  Fragmented Red Cell as a Possible Favorable Prognostic Marker of Hematopoietic Stem Cell Transplantation Associated Thrombotic Microangiopathy.

Authors:  Dong Wook Jekarl; Yonggoo Kim; Jihyang Lim; Myungshin Kim; Kyungja Han; Bin Cho; Hak-Ki Kim; Woo-Sung Min; Chang-Ki Min
Journal:  J Clin Lab Anal       Date:  2014-11-10       Impact factor: 2.352

3.  Comparison between optical microscopy and the Sysmex XN-3000 for schistocyte determination in patients suspected of having schistocytosis.

Authors:  Chattree Hantaweepant; Natthaporn Sasijareonrat; Boonyanuch Chutvanichkul; Khemajira Karaketklang; Yingyong Chinthammitr
Journal:  Health Sci Rep       Date:  2019-11-29
  3 in total