Literature DB >> 11318800

New quantitative parameters on a recently introduced automated blood cell counter--the XE 2100.

C Briggs1, P Harrison, D Grant, J Staves, S J MacHin.   

Abstract

The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count was highly correlated (r = 0.97) with the manual reference count. For counts below 100 x 109/l the 'optical' method and the immunocount gave good a correlation (r = 0.97) optical and impedance counts were also well correlated (r = 0.89). The use of the 'optical' platelet count significantly improves the reliability of low platelet counts. The IG count correlated with visual counts (r = 0.81) and allows the detection of immature cells at an earlier stage in the laboratory process. The introduction of fluorescent flow cytometric analysis allows extended quantification of additional cell populations and so potentially improves screening and monitoring of various pathological conditions.

Mesh:

Year:  2000        PMID: 11318800     DOI: 10.1046/j.1365-2257.2000.00330.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  15 in total

1.  Evaluation of the Sysmex Xe-2100 hematology analyzer in hospital use.

Authors:  Danièle Nakul-Aquaronne; Isabelle Sudaka-Sammarcelli; Corinne Ferrero-Vacher; Benoit Starck; Jacques Bayle
Journal:  J Clin Lab Anal       Date:  2003       Impact factor: 2.352

2.  Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzer.

Authors:  Hisako Shibata; Takahisa Yamane; Ryousuke Yamamura; Kensuke Ohta; Takayuki Takubo; Tomio Kamitani; Masayuki Hino
Journal:  J Clin Lab Anal       Date:  2003       Impact factor: 2.352

3.  Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers.

Authors:  Yuzo Tanaka; Yumiko Tanaka; Kazumi Gondo; Yoshiko Maruki; Tamiaki Kondo; Satomi Asai; Hiromichi Matsushita; Hayato Miyachi
Journal:  J Clin Lab Anal       Date:  2014-03-19       Impact factor: 2.352

4.  Technology and new fluorescence flow cytometry parameters in hematological analyzers.

Authors:  Borros M Arneth; Mario Menschikowki
Journal:  J Clin Lab Anal       Date:  2014-05-05       Impact factor: 2.352

5.  Novel parameters of extended complete blood cell count under fluorescence flow cytometry in patients with sepsis.

Authors:  Borros M Arneth; Maximilian Ragaller; Kathleen Hommel; Oliver Tiebel; Mario Menschikowski; Gabriele Siegert
Journal:  J Clin Lab Anal       Date:  2014-01-06       Impact factor: 2.352

6.  Immature platelet fraction in predicting sepsis in critically ill patients.

Authors:  Roberto Alberto De Blasi; Patrizia Cardelli; Alessandro Costante; Micol Sandri; Marco Mercieri; Roberto Arcioni
Journal:  Intensive Care Med       Date:  2012-10-24       Impact factor: 17.440

7.  5'-AMP impacts lymphocyte recirculation through activation of A2B receptors.

Authors:  Hjalmar R Bouma; Judith N Mandl; Arjen M Strijkstra; Ate S Boerema; Jan-Willem Kok; Annie van Dam; Ad Ijzerman; Frans G M Kroese; Robert H Henning
Journal:  J Leukoc Biol       Date:  2013-05-16       Impact factor: 4.962

8.  Correction of pseudoreticulocytosis in leukocytosis samples using the Sysmex XE-2100 analyzer depends on the type and number of white blood cells.

Authors:  Ahhyun Kim; Joonhong Park; Myungshin Kim; Jihyang Lim; Eun-Jee Oh; Yonggoo Kim; Yeon-Joon Park; Kyungja Han
Journal:  Ann Lab Med       Date:  2012-10-17       Impact factor: 3.464

9.  Maximal load of the vitamin B12 transport system: a study on mice treated for four weeks with high-dose vitamin B12 or cobinamide.

Authors:  Dorte L Lildballe; Elena Mutti; Henrik Birn; Ebba Nexo
Journal:  PLoS One       Date:  2012-10-01       Impact factor: 3.240

10.  Nucleated red blood cells in the blood of medical intensive care patients indicate increased mortality risk: a prospective cohort study.

Authors:  Axel Stachon; Elmar Segbers; Tim Holland-Letz; Reiner Kempf; Steffen Hering; Michael Krieg
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

View more