Literature DB >> 12517856

Evaluation of an enzyme immunoassay technique for detection of antibodies against Treponema pallidum.

Rita Castro1, Emília S Prieto, Irene Santo, Jacinta Azevedo, Filomena da L Exposto.   

Abstract

In the present study, the performance of an enzyme-linked immunosorbent assay (ELISA) technique (Eti-syphilis-G and Eti-syphilis-M; DiaSorin) for detection of Treponema pallidum immunoglobulin M (IgM) and IgG antibodies for the laboratory diagnosis of syphilis was evaluated. Four hundred forty-one samples were studied. The sensitivity and specificity of the ELISA were 100 and 93%, respectively, compared with the results of a microhemagglutination assay for Treponema pallidum (MHA-TP) and 99.4 and 100%, respectively, compared with the results of the fluorescent treponemal antibody absorption (FTA-Abs) test. The results of the ELISA technique were concordant with those of MHA-TP for 98% of the samples tested, while the rate of concordance with the FTA-Abs test was 99.5%. The sensitivities of the rapid plasma reagin (RPR) test, MHA-TP, and the ELISA in the different phases of syphilis compared with the results of the FTA-Abs test were 92, 88, and 100%, respectively, for patients with primary syphilis; 100% for all tests evaluated for patients with secondary syphilis; 97.2, 99.4, and 100%, respectively, for patients with latent syphilis; and 57.9, 92.6, and 97.9%, respectively, for patients with past treated syphilis. The RPR test was reactive with 12 samples that were negative by all the specific tests. IgM antibodies were most frequently detected by the ELISA for IgM antibodies (32.8%) than by the FTA-Abs for IgM antibodies (28.4%). Detection of these antibodies by the FTA-Abs test and the ELISA for IgM antibodies decreased with the stage of disease (72 and 88%, respectively, for patients with primary syphilis to 17 and 19%, respectively, for patients with early latent syphilis). The high sensitivity and specificity of this ELISA technique during all stages of syphilis, together with the fact that it is a simple, objective, and easily automated method, lead us to believe that it could be used as a screening test for syphilis.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12517856      PMCID: PMC149557          DOI: 10.1128/JCM.41.1.250-253.2003

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  17 in total

1.  Comparison of CAPTIA syphilis G enzyme immunoassay with rapid plasma reagin test for detection of syphilis.

Authors:  R P Silletti
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

2.  Evaluation of recomWell Treponema, a novel recombinant antigen-based enzyme-linked immunosorbent assay for the diagnosis of syphilis.

Authors:  V Sambri; A Marangoni; M A Simone; A D'Antuono; M Negosanti; R Cevenini
Journal:  Clin Microbiol Infect       Date:  2001-04       Impact factor: 8.067

3.  Comparison of a recombinant-antigen enzyme immunoassay with Treponema pallidum hemagglutination test for serological confirmation of syphilis.

Authors:  Islay Rodríguez; Elvio L Alvarez; Carmen Fernández; Alina Miranda
Journal:  Mem Inst Oswaldo Cruz       Date:  2002-04       Impact factor: 2.743

4.  Comparative evaluation of nine different enzyme-linked immunosorbent assays for determination of antibodies against Treponema pallidum in patients with primary syphilis.

Authors:  B L Schmidt; M Edjlalipour; A Luger
Journal:  J Clin Microbiol       Date:  2000-03       Impact factor: 5.948

5.  In vitro cultivation of Treponema pallidum: independent confirmation.

Authors:  S J Norris
Journal:  Infect Immun       Date:  1982-04       Impact factor: 3.441

6.  Evaluation of the microenzyme-linked immunosorbent assay with Treponema pallidum antigen.

Authors:  V Pope; E F Hunter; J C Feeley
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

Review 7.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

8.  Screening for treponemal infection by a new enzyme immunoassay.

Authors:  H Young; A Moyes; A McMillan; D H Robertson
Journal:  Genitourin Med       Date:  1989-04

9.  Evaluation of a Treponema pallidum enzyme immunoassay as a screening test for syphilis.

Authors:  N E Hooper; D C Malloy; S Passen
Journal:  Clin Diagn Lab Immunol       Date:  1994-07

10.  Cultivation of virulent Treponema pallidum in tissue culture.

Authors:  A H Fieldsteel; D L Cox; R A Moeckli
Journal:  Infect Immun       Date:  1981-05       Impact factor: 3.441

View more
  14 in total

1.  Evaluation of LIAISON Treponema Screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis.

Authors:  Antonella Marangoni; Vittorio Sambri; Silvia Accardo; Francesca Cavrini; Antonietta D'Antuono; Alessandra Moroni; Elisa Storni; Roberto Cevenini
Journal:  Clin Diagn Lab Immunol       Date:  2005-10

2.  Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

Authors:  Jingna An; Qixia Chen; Qianqian Liu; Chenli Rao; Dongdong Li; Tingting Wang; Chuanmin Tao; Lanlan Wang
Journal:  Clin Vaccine Immunol       Date:  2015-05-13

3.  New proteins for a new perspective on syphilis diagnosis.

Authors:  Brenden C Smith; Yvonne Simpson; Muhammad G Morshed; Laura L E Cowen; Rebecca Hof; Charmaine Wetherell; Caroline E Cameron
Journal:  J Clin Microbiol       Date:  2012-10-24       Impact factor: 5.948

4.  Evaluation of the Determine Syphilis TP assay for the detection of antibodies against Treponema pallidum for the serodiagnosis of syphilis.

Authors:  Y-H Zhuang; Y Tian; Y Chen; J Tang; J-Q Wang; P Li; Q Li; Y-Q Jiang
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-08-25       Impact factor: 3.267

5.  Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies.

Authors:  E Gomez; D J Jespersen; J A Harring; M J Binnicker
Journal:  Clin Vaccine Immunol       Date:  2010-04-28

6.  Laboratory diagnosis of syphilis with automated immunoassays.

Authors:  Antonella Marangoni; Alessandra Moroni; Silvia Accardo; Roberto Cevenini
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

7.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22

8.  Comparative evaluation of 15 serological assays for the detection of syphilis infection.

Authors:  M J Cole; K R Perry; J V Parry
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2007-10       Impact factor: 3.267

Review 9.  The Laboratory Diagnosis of Syphilis.

Authors:  Ferris Satyaputra; Stephanie Hendry; Maxwell Braddick; Pirathaban Sivabalan; Robert Norton
Journal:  J Clin Microbiol       Date:  2021-05-12       Impact factor: 5.948

10.  Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.

Authors:  Aseem K Tiwari; Prashant K Pandey; Ravi C Dara; Ganesh S Rawat; Vimarsh Raina; Richa Bhargava
Journal:  Asian J Transfus Sci       Date:  2015 Jan-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.