Literature DB >> 11422242

Evaluation of recomWell Treponema, a novel recombinant antigen-based enzyme-linked immunosorbent assay for the diagnosis of syphilis.

V Sambri1, A Marangoni, M A Simone, A D'Antuono, M Negosanti, R Cevenini.   

Abstract

OBJECTIVE: To evaluate the diagnostic performance of an enzyme immunosorbent assay (recomWell Treponema) for the diagnosis of syphilis. The novel recombinant antigens Tpn47, TpN17 and TpN15 were utilized.
METHODS: A total of 782 human serum specimens, belonging to four different categories (blood donors, n = 200; routine laboratory screening for syphilis, n = 400; syphilis patients, n = 122; potential cross-reactors, n = 60), were evaluated to compare the sensitivity and specificity of the recomWell Treponema kit with a standard whole Treponema pallidum cell lysate antigen-based ELISA (Syphilis Screening) and with micro-haemagglutination (MHA-TP).
RESULTS: The overall specificity and sensitivity of the recomWell Treponema IgG was 98.9% and 98.3%, respectively. The specificity and sensitivity of Syphilis Screening ELISA was 98.7% and 98.3%, respectively. The agreement between recomWell Treponema and Syphilis Screening was 100%, 97.8%, 95.9% and 95% among the blood donor specimens, screening samples, syphilis specimens and the potential cross-reactors, respectively. Values of concordance varying from 96.7% to 98.3% were found in the different groups of sera between recomWell Treponema and MHA-TP. In addition, recomWell Treponema demonstrated a good diagnostic performance when used to detect the IgM to T. pallidum. No false-positive sera were identified and, in 17/19 samples from primary infection, an IgM immune response was found.
CONCLUSIONS: recomWell Treponema was shown to be a highly specific and sensitive method in all stages of syphilis screening and it can be considered as alternative to other ELISA tests based on native antigen preparations.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11422242     DOI: 10.1046/j.1469-0691.2001.00232.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  15 in total

1.  Evaluation of an enzyme immunoassay technique for detection of antibodies against Treponema pallidum.

Authors:  Rita Castro; Emília S Prieto; Irene Santo; Jacinta Azevedo; Filomena da L Exposto
Journal:  J Clin Microbiol       Date:  2003-01       Impact factor: 5.948

2.  Evaluation of a new particle gel immunoassay for determination of antibodies against Treponema pallidum.

Authors:  Bruno L Schmidt
Journal:  J Clin Microbiol       Date:  2004-06       Impact factor: 5.948

3.  Evaluation of LIAISON Treponema Screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis.

Authors:  Antonella Marangoni; Vittorio Sambri; Silvia Accardo; Francesca Cavrini; Antonietta D'Antuono; Alessandra Moroni; Elisa Storni; Roberto Cevenini
Journal:  Clin Diagn Lab Immunol       Date:  2005-10

Review 4.  Biological basis for syphilis.

Authors:  Rebecca E Lafond; Sheila A Lukehart
Journal:  Clin Microbiol Rev       Date:  2006-01       Impact factor: 26.132

5.  Performance evaluation of the Elecsys syphilis assay for the detection of total antibodies to Treponema pallidum.

Authors:  Martin Enders; Andrea Hunjet; Michael Gleich; Roland Imdahl; Annelies Mühlbacher; Harald Schennach; Kriangsak Chaiwong; Tasanee Sakuldamrongpanich; Ajda Turhan; Rüchan Sertöz; Eva Wolf; Wolfgang Mayer; Chuanmin Tao; Lan Lan Wang; Simona Semprini; Vittorio Sambri
Journal:  Clin Vaccine Immunol       Date:  2014-10-29

6.  Establishment and Evaluation of a One-Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum.

Authors:  Lijuan Liu; Yuling Xie; Zhenxian Dai; Chuanshang Zhuo; Yushui Wu
Journal:  J Clin Lab Anal       Date:  2014-10-02       Impact factor: 2.352

7.  Laboratory diagnosis of syphilis with automated immunoassays.

Authors:  Antonella Marangoni; Alessandra Moroni; Silvia Accardo; Roberto Cevenini
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

8.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22

9.  Comparative evaluation of 15 serological assays for the detection of syphilis infection.

Authors:  M J Cole; K R Perry; J V Parry
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2007-10       Impact factor: 3.267

10.  Evaluation of the recombinant protein TpF1 of Treponema pallidum for serodiagnosis of syphilis.

Authors:  Chuanhao Jiang; Feijun Zhao; Jinhong Xiao; Tiebing Zeng; Jian Yu; Xiaohua Ma; Haiying Wu; Yimou Wu
Journal:  Clin Vaccine Immunol       Date:  2013-08-14