Literature DB >> 25972403

Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

Jingna An1, Qixia Chen1, Qianqian Liu1, Chenli Rao1, Dongdong Li1, Tingting Wang1, Chuanmin Tao2, Lanlan Wang2.   

Abstract

The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories.
Copyright © 2015, American Society for Microbiology. All Rights Reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25972403      PMCID: PMC4478528          DOI: 10.1128/CVI.00116-15

Source DB:  PubMed          Journal:  Clin Vaccine Immunol        ISSN: 1556-679X


  27 in total

1.  Evaluation of an enzyme immunoassay technique for detection of antibodies against Treponema pallidum.

Authors:  Rita Castro; Emília S Prieto; Irene Santo; Jacinta Azevedo; Filomena da L Exposto
Journal:  J Clin Microbiol       Date:  2003-01       Impact factor: 5.948

Review 2.  Syphilis: using modern approaches to understand an old disease.

Authors:  Emily L Ho; Sheila A Lukehart
Journal:  J Clin Invest       Date:  2011-12-01       Impact factor: 14.808

3.  It is time to use treponema-specific antibody screening tests for diagnosis of syphilis.

Authors:  Michael J Loeffelholz; Matthew J Binnicker
Journal:  J Clin Microbiol       Date:  2011-11-16       Impact factor: 5.948

4.  The Architect Syphilis assay for antibodies to Treponema pallidum: an automated screening assay with high sensitivity in primary syphilis.

Authors:  H Young; J Pryde; L Duncan; J Dave
Journal:  Sex Transm Infect       Date:  2008-09-12       Impact factor: 3.519

5.  [Evaluation of latex agglutination test for anti-treponemal antibody in comparison with chemical luminescence tests].

Authors:  Naomi Watanabe; Ritsuko Nagatomo; Shigeo Okubo; Hiromitsu Yokota; Hitoshi Ikeda; Yutaka Yatomi
Journal:  Rinsho Byori       Date:  2011-02

6.  Treponema-specific tests for serodiagnosis of syphilis: comparative evaluation of seven assays.

Authors:  M J Binnicker; D J Jespersen; L O Rollins
Journal:  J Clin Microbiol       Date:  2011-02-23       Impact factor: 5.948

Review 7.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

8.  Serological diagnosis of syphilis: comparison of the Trep-Chek IgG enzyme immunoassay with other screening and confirmatory tests.

Authors:  Raymond S W Tsang; Irene E Martin; Allan Lau; Pam Sawatzky
Journal:  FEMS Immunol Med Microbiol       Date:  2007-10

9.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22

10.  Comparative evaluation of 15 serological assays for the detection of syphilis infection.

Authors:  M J Cole; K R Perry; J V Parry
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2007-10       Impact factor: 3.267

View more
  5 in total

1.  Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

Authors:  Daniel A Ortiz; Michael J Loeffelholz
Journal:  J Clin Microbiol       Date:  2017-09-06       Impact factor: 5.948

2.  Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum.

Authors:  Dongdong Li; Jingna An; Tingting Wang; Chuanmin Tao; Lanlan Wang
Journal:  J Clin Lab Anal       Date:  2016-05-26       Impact factor: 2.352

3.  Comparison of Roche Elecsys and Sysmex HISCL immunoassays for the screening of common blood-borne pathogens.

Authors:  Wanzhou Xu; Yongqing Tong; Yan Li
Journal:  Ann Transl Med       Date:  2019-07

4.  Comparison of "Lumipulse anti-Treponema pallidum" and "Architect Syphilis TP" and further examination.

Authors:  Jianbo Liang; Jianxin Wan; Chumei Huang; Gaorong Cai; Laisheng Li; Min Liu
Journal:  J Clin Lab Anal       Date:  2020-01-24       Impact factor: 2.352

5.  Surgical treatment of syphilitic superficial femoral artery aneurysm: a rare case report.

Authors:  Zhihua Cheng; Sean X Luo; Xiwei Sun; Siqiao Sun; Zhongying Wang; Yuzhu Jiang; Zhiyuan An; Qi Wang
Journal:  BMC Infect Dis       Date:  2015-11-20       Impact factor: 3.090

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.