Literature DB >> 12507338

A triaxial accelerometer for measuring arm movements.

Eva Bernmark1, Christina Wiktorin.   

Abstract

A triaxial accelerometer used as an inclinometer (INC) (Logger Technology, Sweden) needed to be evaluated for field measurements of arm postures and movements. INC consists of one portable data logger and up to four sensors. Each sensor measures the inclination to the vertical line. The sampling frequency is 20 Hz and, the logger can collect data for up to 12 h. The aim of the present study was to compare INC measurements with those from an optoelectronic measuring system- the Mac Reflex system (OPT) (Qualisys AB, Sweden). For all movements with normal to high velocities INC measured the degree of arm elevation with very high precision. At very high velocities and, especially when the direction of the velocity was perpendicular to the vertical line the largest differences between INC and OPT were found. In field studies INC has proved to be very safe and useful in assessment of arm movements. INC was easy to handle and easy to wear for the researcher and the subject, respectively.

Mesh:

Year:  2002        PMID: 12507338     DOI: 10.1016/s0003-6870(02)00072-8

Source DB:  PubMed          Journal:  Appl Ergon        ISSN: 0003-6870            Impact factor:   3.661


  21 in total

1.  Global positioning system and sport-specific testing.

Authors:  Peter Larsson
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

2.  Validation of an accelerometer for determination of muscle belly radial displacement.

Authors:  T Zagar; D Krizaj
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

3.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers.

Authors:  H J Luinge; P H Veltink
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

4.  Bioharness(™) multivariable monitoring device: part. I: validity.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

5.  Bioharness(™) Multivariable Monitoring Device: Part. II: Reliability.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

6.  Statistical Prediction of Hand Force Exertion Levels in a Simulated Push Task using Posture Kinematics.

Authors:  Sol Lim; Clive D'Souza
Journal:  Proc Hum Factors Ergon Soc Annu Meet       Date:  2017-09-28

7.  The reliability of side to side measurements of upper extremity activity levels in healthy subjects.

Authors:  Miguel Acuna; Tal Amasay; Andrew R Karduna
Journal:  BMC Musculoskelet Disord       Date:  2010-07-22       Impact factor: 2.362

8.  Objective assessment of shoulder mobility with a new 3D gyroscope--a validation study.

Authors:  Bilal Farouk El-Zayat; Turgay Efe; Annett Heidrich; Udo Wolf; Nina Timmesfeld; Thomas J Heyse; Stefan Lakemeier; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2011-07-21       Impact factor: 2.362

9.  Continuous monitoring of upper-limb activity in a free-living environment: a validation study.

Authors:  A Vega-Gonzalez; B J Bain; P M Dall; M H Granat
Journal:  Med Biol Eng Comput       Date:  2007-07-28       Impact factor: 2.602

10.  The association between back pain and trunk posture of workers in a special school for the severe handicaps.

Authors:  Kelvin C H Wong; Raymond Y W Lee; Simon S Yeung
Journal:  BMC Musculoskelet Disord       Date:  2009-04-29       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.