Literature DB >> 24149346

Bioharness(™) multivariable monitoring device: part. I: validity.

James A Johnstone1, Paul A Ford, Gerwyn Hughes, Tim Watson, Andrew T Garrett.   

Abstract

The Bioharness(™) monitoring system may provide physiological information on human performance but there is limited information on its validity. The objective of this study was to assess the validity of all 5 Bioharness(™) variables using a laboratory based treadmill protocol. 22 healthy males participated. Heart rate (HR), Breathing Frequency (BF) and Accelerometry (ACC) precision were assessed during a discontinuous incremental (0-12 km·h(-1)) treadmill protocol. Infra-red skin temperature (ST) was assessed during a 45 min(-1) sub-maximal cycle ergometer test, completed twice, with environmental temperature controlled at 20 ± 0.1 °C and 30 ± 0.1 °C. Posture (P) was assessed using a tilt table moved through 160°. Adopted precision of measurement devices were; HR: Polar T31 (Polar Electro), BF: Spirometer (Cortex Metalyser), ACC: Oxygen expenditure (Cortex Metalyser), ST: Skin thermistors (Grant Instruments), P:Goniometer (Leighton Flexometer). Strong relationships (r = .89 to .99, p < 0.01) were reported for HR, BF, ACC and P. Limits of agreement identified differences in HR (-3.05 ± 32.20 b·min(-1)), BF (-3.46 ± 43.70 br·min(-1)) and P (0.20 ± 2.62°). ST established a moderate relationships (-0.61 ± 1.98 °C; r = 0.76, p < 0.01). Higher velocities on the treadmill decreased the precision of measurement, especially HR and BF. Global results suggest that the BioharressTM is a valid multivariable monitoring device within the laboratory environment. Key pointsDifferent levels of precision exist for each variable in the Bioharness(™) (Version 1) multi-variable monitoring deviceAccelerometry and posture variables presented the most precise dataData from the heart rate and breathing frequency variable decrease in precision at velocities ≥ 10 km·h(-1)Clear understanding of the limitations of new applied monitoring technology is required before it is used by the exercise scientist.

Entities:  

Keywords:  Physiological technology; exercise; precision of measurement

Year:  2012        PMID: 24149346      PMCID: PMC3737934     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  34 in total

Review 1.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

2.  Reexamination of validity and reliability of the CSA monitor in walking and running.

Authors:  Søren Brage; Niels Wedderkopp; Paul W Franks; Lars Bo Andersen; Karsten Froberg
Journal:  Med Sci Sports Exerc       Date:  2003-08       Impact factor: 5.411

3.  Tidal volume and respiratory timing derived from a portable ventilation monitor.

Authors:  F Dennis McCool; John Wang; Kristi L Ebi
Journal:  Chest       Date:  2002-08       Impact factor: 9.410

4.  Heart monitoring garments using textile electrodes for healthcare applications.

Authors:  Hyun-Seung Cho; Su-Min Koo; Joohyeon Lee; Hakyung Cho; Da-Hye Kang; Ha-Young Song; Jeong-Whan Lee; Kang-Hwi Lee; Young-Jae Lee
Journal:  J Med Syst       Date:  2009-08-11       Impact factor: 4.460

5.  Three types of skin-surface thermometers: a comparison of reliability, validity, and responsiveness.

Authors:  Robert S Burnham; Robert S McKinley; Daniel D Vincent
Journal:  Am J Phys Med Rehabil       Date:  2006-07       Impact factor: 2.159

6.  Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat.

Authors:  Michael J Buono; Amy Jechort; Raquel Marques; Carrie Smith; Jessica Welch
Journal:  Physiol Meas       Date:  2007-07-06       Impact factor: 2.833

7.  The precision and accuracy of a portable heart rate monitor.

Authors:  B L Seaward; R H Sleamaker; T McAuliffe; J F Clapp
Journal:  Biomed Instrum Technol       Date:  1990 Jan-Feb

Review 8.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

9.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

10.  Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph.

Authors:  Christian F Clarenbach; Oliver Senn; Thomas Brack; Malcolm Kohler; Konrad E Bloch
Journal:  Chest       Date:  2005-09       Impact factor: 9.410

View more
  30 in total

1.  Complexity of physiological responses decreases in high-stress musical performance.

Authors:  Aaron Williamon; Lisa Aufegger; David Wasley; David Looney; Danilo P Mandic
Journal:  J R Soc Interface       Date:  2013-09-25       Impact factor: 4.118

2.  Field based reliability and validity of the bioharness™ multivariable monitoring device.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew C S Mitchell; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

3.  Accelerometery and Heart Rate Responses of Professional Fast-Medium Bowlers in One-Day and Multi-Day Cricket.

Authors:  James A Johnstone; Gerwyn Hughes; Andrew C Mitchell; Paul A Ford; Tim Watson; Rob Duffield; Dan Gordon; Justin D Roberts; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2017-08-08       Impact factor: 2.988

4.  Physiological Responses to Active Video Games Compared to Treadmill Walking and TV Watching in Obese Children and Adolescents.

Authors:  Ramzi Majaj; Trent Scott; Ryan Moran; Dana Kimberly; Tamekia Jones; Webb Smith
Journal:  Int J Exerc Sci       Date:  2021-04-01

5.  Design and evaluation of a ubiquitous chest-worn cardiopulmonary monitoring system for healthcare application: a pilot study.

Authors:  Jiewen Zheng; Congying Ha; Zhengbo Zhang
Journal:  Med Biol Eng Comput       Date:  2016-05-13       Impact factor: 2.602

6.  The Role of Volume Regulation and Thermoregulation in AKI during Marathon Running.

Authors:  Sherry G Mansour; Thomas G Martin; Wassim Obeid; Rachel W Pata; Karen M Myrick; Lidiya Kukova; Yaqi Jia; Petter Bjornstad; Joe M El-Khoury; Chirag R Parikh
Journal:  Clin J Am Soc Nephrol       Date:  2019-08-14       Impact factor: 8.237

7.  Treadmill exercise improves fitness and reduces craving and use of cocaine in individuals with concurrent cocaine and tobacco-use disorder.

Authors:  Richard De La Garza; Jin H Yoon; Daisy G Y Thompson-Lake; Colin N Haile; Joel D Eisenhofer; Thomas F Newton; James J Mahoney
Journal:  Psychiatry Res       Date:  2016-08-09       Impact factor: 3.222

Review 8.  Planetary extravehicular activity (EVA) risk mitigation strategies for long-duration space missions.

Authors:  Blaze Belobrajdic; Kate Melone; Ana Diaz-Artiles
Journal:  NPJ Microgravity       Date:  2021-05-12       Impact factor: 4.415

9.  Psychometric properties of the Zephyr bioharness device: a systematic review.

Authors:  Goris Nazari; Pavlos Bobos; Joy C MacDermid; Kathryn E Sinden; Julie Richardson; Ada Tang
Journal:  BMC Sports Sci Med Rehabil       Date:  2018-02-21

10.  Core and Whole Body Vibration Exercise Influences Muscle Sensitivity and Posture during a Military Foot March.

Authors:  Kaitlin D Lyons; Aaron G Parks; Oluwagbemiga Dadematthews; Nilophar Zandieh; Paige McHenry; Kenneth E Games; Michael D Goodlett; William Murrah; Jaimie Roper; JoEllen M Sefton
Journal:  Int J Environ Res Public Health       Date:  2021-05-07       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.