Literature DB >> 12439232

Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem.

Michele F Surace1, Aivars Berzins, Robert M Urban, Joshua J Jacobs, Richard A Berger, Raghu N Natarajan, Thomas P Andriacchi, Jorge O Galante.   

Abstract

Wear and deformation were characterized at the backsurface of 25 posterior cruciate-retaining total knee arthroplasty polyethylene inserts retrieved postmortem from 20 subjects. The mean implantation time was 64.1 months (range, 4-156 months). The backsurface of the inserts was inspected using a stereomicroscope with a digital optical system. Coronal histologic sections of 13 proximal tibias were inspected for the presence and extent of penetration of granuloma. Damage to the backsurface was limited. Polishing was recorded on 21 (84%) of the inserts and abrasive wear on five (20%) inserts. Pitting was present in 21 (84%) components, but involved less than 1% of the area in all but one of these components. Delamination and cracking were not observed. Extrusions were seen in all 10 of the components that had screw holes in the tibial tray. A correlation was found between the depth of penetration of the granuloma along the posteromedial screw and the height of the corresponding extrusion. The anteroposterior profiles showed a concave deformation of the backsurface in 24 (96 %) of the cases. The concave deformation of tibial inserts may facilitate accumulation and transportation of wear debris to the tibial bone-implant interface through the screw holes in implants designed for cementless fixation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12439232     DOI: 10.1097/00003086-200211000-00004

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  11 in total

1.  [Proposal for the classification of the periprosthetic membrane from loosened hip and knee endoprostheses].

Authors:  L Morawietz; Th Gehrke; R-A Classen; B Barden; M Otto; T Hansen; Th Aigner; P Stiehl; J Neidel; J H Schröder; L Frommelt; Th Schubert; C Meyer-Scholten; A König; Ph Ströbel; Ch P Rader; S Kirschner; F Lintner; W Rüther; A Skwara; I Bos; J Kriegsmann; V Krenn
Journal:  Pathologe       Date:  2004-09       Impact factor: 1.011

2.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

3.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

4.  A pictographic atlas for classifying damage modes on polyethylene bearings.

Authors:  Melinda Harman; Luca Cristofolini; Paolo Erani; Susanna Stea; Marco Viceconti
Journal:  J Mater Sci Mater Med       Date:  2011-04-02       Impact factor: 3.896

5.  Proposal for a histopathological consensus classification of the periprosthetic interface membrane.

Authors:  L Morawietz; R-A Classen; J H Schröder; C Dynybil; C Perka; A Skwara; J Neidel; T Gehrke; L Frommelt; T Hansen; M Otto; B Barden; T Aigner; P Stiehl; T Schubert; C Meyer-Scholten; A König; P Ströbel; C P Rader; S Kirschner; F Lintner; W Rüther; I Bos; C Hendrich; J Kriegsmann; V Krenn
Journal:  J Clin Pathol       Date:  2006-06       Impact factor: 3.411

6.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

7.  An autonomous mathematical reconstruction to effectively measure volume loss on retrieved polyethylene tibial inserts.

Authors:  Christopher B Knowlton; Markus A Wimmer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-08-22       Impact factor: 3.368

8.  Backside wear in modern total knee designs.

Authors:  Prakash Jayabalan; Bridgette D Furman; Jocelyn M Cottrell; Timothy M Wright
Journal:  HSS J       Date:  2007-02

9.  Backside wear of tibial polyethylene components is affected by gait pattern: A knee simulator study using rare earth tracer technology.

Authors:  Valentina Ngai; Joachim Kunze; Johannes Cip; Michel P Laurent; Joshua J Jacobs; Markus A Wimmer
Journal:  J Orthop Res       Date:  2020-05-25       Impact factor: 3.494

10.  A rare case of bilateral large osteolysis following cemented and cementless total knee arthroplasties.

Authors:  Julian Dexel; Stephan Kirschner; Melinda K Harman; Jörg Lützner
Journal:  Acta Orthop       Date:  2012-12-17       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.