Literature DB >> 12271399

Digital radiography with large-area flat-panel detectors.

E Kotter1, M Langer.   

Abstract

Large-area flat-panel detectors with active readout mechanisms have been on the market for the past 2 years. This article describes different detector technologies. An important distinction is made between detectors with direct and those with indirect conversion of X-rays into electrical charges. Detectors with indirect conversion are built with unstructured or structured scintillators, the latter resulting in less lateral diffusion of emitted light. Some important qualities of flat-panel detectors are discussed. The first phantom and clinical studies published report an image quality at least comparable to that of screen-film systems and a potential for dose reduction. The available studies are summarised in this article.

Entities:  

Mesh:

Year:  2002        PMID: 12271399     DOI: 10.1007/s00330-002-1350-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

Authors:  Jens Ricke; Frank Fischbach; Torsten Freund; Ulf Teichgräber; Enrique Lopez Hänninen; Rainer Röttgen; Ulrike Engert; Hermann Eichstädt; Roland Felix
Journal:  Eur Radiol       Date:  2003-06-19       Impact factor: 5.315

Review 2.  Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature.

Authors:  Markus Völk; Okka W Hamer; Stefan Feuerbach; Michael Strotzer
Journal:  Eur Radiol       Date:  2004-02-17       Impact factor: 5.315

3.  Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement.

Authors:  K Eklund; K Jonsson; G Lindblom; B Lundin; J Sanfridsson; M Sloth; B Sivberg
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

4.  Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques.

Authors:  Ibrahim Aboshady; Dianna D Cody; Evan M Johnson; Amir Gahremanpour; Deborah Vela; Kamal G Khalil; Herbert L Dupont; James T Willerson; L Maximilian Buja; Gregory W Gladish
Journal:  Int J Cardiol       Date:  2010-12-24       Impact factor: 4.164

5.  Cellular death but not genetic damage in oral mucosa cells after exposure to digital lateral radiography.

Authors:  Daniel A Ribeiro; Eduardo K Sannomiya; Renan Pozzi; Sandra R Miranda; Fernanda Angelieri
Journal:  Clin Oral Investig       Date:  2010-03-25       Impact factor: 3.573

6.  Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

Authors:  Konstantin Nikolaou; Thomas Flohr; Karl Stierstorfer; Christoph R Becker; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2004-11-20       Impact factor: 5.315

Review 7.  Digital detectors for mammography: the technical challenges.

Authors:  A Noel; F Thibault
Journal:  Eur Radiol       Date:  2004-10-08       Impact factor: 5.315

8.  Flat detectors and their clinical applications.

Authors:  Martin Spahn
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

9.  Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

Authors:  Wouter J H Veldkamp; Lucia J M Kroft; Mireille V Boot; Bart J A Mertens; Jacob Geleijns
Journal:  Eur Radiol       Date:  2005-08-31       Impact factor: 5.315

10.  Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

Authors:  Juergen Biederer; Tobias Gottwald; Hendrik Bolte; Christian Riedel; Sandra Freitag; Richard Van Metter; Martin Heller
Journal:  Eur Radiol       Date:  2006-09-09       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.