Literature DB >> 12181223

Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method.

Y Ueda1, T Hozumi, K Yoshida, H Watanabe, T Akasaka, T Takagi, A Yamamuro, S Homma, J Yoshikawa.   

Abstract

BACKGROUND: The recent introduction of the automated cardiac flow measurement (ACM) method, using spatiotemporal integration of the Doppler velocity profile, provides a quick and accurate automated calculation of cardiac output.
OBJECTIVE: To evaluate the ACM method against oximetry during cardiac catheterisation for estimating the Qp/Qs (pulmonary to systemic flow) ratio in patients with an atrial septal defect.
METHODS: Left and right ventricular stroke volume (LVSV, RVSV) were calculated by ACM in 22 patients with an atrial septal defect who underwent cardiac catheterisation and in 11 patients without heart disease (control group). With ACM, the Qp/Qs ratio was estimated from RVSV divided by LVSV. In the patients with an atrial septal defect, the Qp/Qs ratio was assessed by oximetry at the time of cardiac catheterisation.
RESULTS: There was a good correlation between LVSV and RVSV obtained by ACM in the control group (r = 0.98, y = 0.97x + 0.25, SEE = 2.9 ml). The mean difference between LVSV and RVSV by ACM was -1.25 (2.76) ml. The Qp/Qs ratio obtained by ACM in the control group was 0.98 (0.06). The Qp/Qs ratio in patients with an atrial septal defect was significantly higher than in the control group (3.11 (1.20), p < 0.001). ACM determination of the Qp/Qs ratio correlated well with oximetry determination (r = 0.86, y = 0.75x + 0.55, SEE = 0.64). The mean difference between ACM and oximetry for the measurement of the Qp/Qs ratio was -0.28 (0.69).
CONCLUSIONS: The newly developed ACM method is clinically useful for non-invasive automated estimations of the Qp/Qs ratio in patients with an atrial septal defect.

Entities:  

Mesh:

Year:  2002        PMID: 12181223      PMCID: PMC1767348          DOI: 10.1136/heart.88.3.278

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  18 in total

1.  Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model.

Authors:  T Shiota; M Jones; S Aida; M Chikada; H Tsujino; T El-Kadi; D J Sahn
Journal:  J Am Coll Cardiol       Date:  1999-08       Impact factor: 24.094

2.  Noninvasive assessment of hemodynamic subsets in patients with acute myocardial infarction using digital color Doppler velocity profile integration and pulmonary venous flow analysis.

Authors:  T Hozumi; K Yoshida; I Mori; T Akasaka; T Takagi; S Kaji; T Kawamoto; Y Ueda; S Morioka
Journal:  Am J Cardiol       Date:  1999-04-01       Impact factor: 2.778

3.  Automated assessment of mitral regurgitant volume and regurgitant fraction by a newly developed digital color Doppler velocity profile integration method.

Authors:  T Hozumi; K Yoshida; T Akasaka; T Takagi; A Yamamuro; T Yagi; J Yoshikawa
Journal:  Am J Cardiol       Date:  1997-11-15       Impact factor: 2.778

4.  Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method.

Authors:  H Tsujino; E Shiki; M Hirama; K Iinuma
Journal:  J Am Soc Echocardiogr       Date:  1995 Sep-Oct       Impact factor: 5.251

5.  Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation.

Authors:  T Shiota; M Jones; S Aida; H Tsujino; I Yamada; A Delabays; N G Pandian; D J Sahn
Journal:  J Am Coll Cardiol       Date:  1997-09       Impact factor: 24.094

6.  A new Doppler method for quantification of volumetric flow: in vivo validation using color Doppler.

Authors:  W Y Kim; J K Poulsen; K Terp; N H Staalsen
Journal:  J Am Coll Cardiol       Date:  1996-01       Impact factor: 24.094

7.  Measurement of systemic and pulmonary blood flow and QP/QS ratio using Doppler and two-dimensional echocardiography.

Authors:  S P Sanders; S Yeager; R G Williams
Journal:  Am J Cardiol       Date:  1983-03-15       Impact factor: 2.778

8.  Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation.

Authors:  J P Sun; M Pu; F M Fouad; R Christian; W J Stewart; J D Thomas
Journal:  Circulation       Date:  1997-02-18       Impact factor: 29.690

9.  Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation.

Authors:  J P Sun; X S Yang; J X Qin; N L Greenberg; J Zhou; C J Vazquez; B P Griffin; W J Stewart; J D Thomas
Journal:  J Am Coll Cardiol       Date:  1998-10       Impact factor: 24.094

10.  Estimation of volume flow rate by surface integration of velocity vectors from color Doppler images.

Authors:  Y Sun; P Ask; B Janerot-Sjöberg; L Eidenvall; D Loyd; B Wranne
Journal:  J Am Soc Echocardiogr       Date:  1995 Nov-Dec       Impact factor: 5.251

View more
  2 in total

1.  Automated cardiac flow measurement by digital colour Doppler echocardiography.

Authors:  T Shiota
Journal:  Heart       Date:  2002-09       Impact factor: 5.994

2.  Can intraoperative TEE correctly measure residual shunt after surgical repair of ventricular septal defects?

Authors:  Satoshi Kurokawa; Takayuki Honma; Miki Taneoka; Hidekazu Imai; Hiroshi Baba; Minoru Nomura
Journal:  J Anesth       Date:  2010-03-13       Impact factor: 2.078

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.