Literature DB >> 20229003

Can intraoperative TEE correctly measure residual shunt after surgical repair of ventricular septal defects?

Satoshi Kurokawa1, Takayuki Honma, Miki Taneoka, Hidekazu Imai, Hiroshi Baba, Minoru Nomura.   

Abstract

PURPOSE: No groups have yet succeeded in identifying the need for re-repair of residual shunt after surgical repair of ventricular septal defect (VSD) based on quantitative evaluation of the ratio of the pulmonary blood flow to the systemic blood flow (Qp/Qs) by transesophageal echocardiography (TEE). Hence, we studied the accuracy of Qp/Qs as estimated by intraoperative TEE.
METHODS: Twenty-six patients undergoing VSD closure were studied. After separation from the cardiopulmonary bypass, the presence and severity of residual leakage was evaluated by color Doppler image, and the Qp/Qs (TEE-derived Qp/Qs) was calculated by measuring the vessel diameter and the velocity-time integral of the flow profiles in the main pulmonary artery and left ventricular outflow tract. Transthoracic echocardiography (TTE) was performed at pre-discharge and at 6-12 months after the correction to confirm the presence and severity of residual leakage.
RESULTS: TEE detected only minor leakage, with no indication for re-repair, in 8 of the 26 patients. Nevertheless, TEE-derived Qp/Qs varied from 0.57 to 2.07 and were incorrect in 17 patients (65.4%). This meant that when TEE-derived Qp/Qs was outside the acceptable range, the patient was judged not to be in need of re-repair. TTE at pre-discharge confirmed trivial leakage in 3 patients in whom TEE had also identified similar leakages. These leakages were not observed at the follow-up TTE.
CONCLUSION: TEE-derived Qp/Qs lacks the accuracy required to play a crucial role in quantitatively measuring the severity of residual shunt, while two-dimensional TEE can reliably detect residual leakage after VSD closure and lead to optimal judgment on the need for re-repair.

Entities:  

Mesh:

Year:  2010        PMID: 20229003     DOI: 10.1007/s00540-010-0896-3

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  21 in total

1.  Pulsed wave Doppler measurement of cardiac output from the right ventricular outflow tract.

Authors:  A Maslow; M E Comunale; J M Haering; J Watkins
Journal:  Anesth Analg       Date:  1996-09       Impact factor: 5.108

2.  Noninvasive assessment of left-to-right shunting in ventricular septal defects by the proximal isovelocity surface area method on Doppler colour flow mapping.

Authors:  Mustafa Kosecik; Gul Sagin-Saylam; Nurettin Unal; Mustafa Kir; Sebnem Paytoncu
Journal:  Can J Cardiol       Date:  2007-11       Impact factor: 5.223

3.  Transesophageal transgastric echocardiography in infants and children: the subcostal view equivalent.

Authors:  I A Muhiudeen; N H Silverman; R H Anderson
Journal:  J Am Soc Echocardiogr       Date:  1995 May-Jun       Impact factor: 5.251

4.  Transesophageal echocardiography during repair of congenital cardiac defects: identification of residual problems necessitating reoperation.

Authors:  J G Stevenson; G K Sorensen; D M Gartman; D G Hall; E A Rittenhouse
Journal:  J Am Soc Echocardiogr       Date:  1993 Jul-Aug       Impact factor: 5.251

5.  Comparison of thermodilution bolus cardiac output and Doppler cardiac output in the early post-cardiopulmonary bypass period.

Authors:  Xiaoqin Zhao; John S Mashikian; Pete Panzica; Adam Lerner; Kyung W Park; Mark E Comunale
Journal:  J Cardiothorac Vasc Anesth       Date:  2003-04       Impact factor: 2.628

6.  Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve.

Authors:  P L Darmon; Z Hillel; A Mogtader; B Mindich; D Thys
Journal:  Anesthesiology       Date:  1994-04       Impact factor: 7.892

7.  Transatrial septal velocity measurement by Doppler echocardiography in atrial septal defect: correlation with Qp:Qs ratio.

Authors:  G R Marx; H D Allen; S J Goldberg; C J Flinn
Journal:  Am J Cardiol       Date:  1985-04-15       Impact factor: 2.778

8.  Doppler evaluation of left to right shunt (Qp/Qs) in patients with isolated ventricular septal defect (Vsd).

Authors:  M Mahmood; S S Haque; M A Siddique; C M Ahmed; Z Hossain
Journal:  Mymensingh Med J       Date:  2007-07

9.  Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method.

Authors:  Y Ueda; T Hozumi; K Yoshida; H Watanabe; T Akasaka; T Takagi; A Yamamuro; S Homma; J Yoshikawa
Journal:  Heart       Date:  2002-09       Impact factor: 5.994

10.  Utility of intraoperative transesophageal echocardiography in the assessment of residual cardiac defects.

Authors:  H M Rosenfeld; T L Gentles; G Wernovsky; P C Laussen; R A Jonas; J E Mayer; S D Colan; S P Sanders; M E van der Velde
Journal:  Pediatr Cardiol       Date:  1998 Jul-Aug       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.