Literature DB >> 9054753

Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation.

J P Sun1, M Pu, F M Fouad, R Christian, W J Stewart, J D Thomas.   

Abstract

BACKGROUND: A new Doppler echocardiographic technique has been developed for automated cardiac output measurement (ACOM) that assumes neither a flat flow profile nor collinearity with the scan line, but clinical validation of this method is lacking. METHODS AND
RESULTS: In 165 subjects (50 intensive care patients, 10 dobutamine echocardiography patients, and 105 normal volunteers; age, 49.4 +/- 19.3 years; 92 men), ACOM was performed in the left ventricular outflow tract (LVOT), with the color baseline shifted to avoid aliasing. ACOM was also tested in a pulsatile in vitro model. Stroke volume was calculated by double integration of Doppler signals in space (across the LVOT) and in time (through the systolic period), assuming hemiaxial symmetry: integral of integral of pi r v(r,t) dr dt, where v(r,t) is the velocity at a distance r from the center of the LVOT at time t during systole. Stroke volume from ACOM was compared with thermodilution (TD), aortic valve pulsed-wave Doppler (PWAO), and left ventricular echocardiographic (two-dimensional [2D]) methods. There was good correlation between ACOM and PWAO (r = .93). TD (r = .86), and 2D (r = .74), with close agreement seen. ACOM had higher correlation and agreement with TD than did either PWAO (P < .02) or 2D (P < .01). ACOM was also able to track accurately the changes in cardiac output with dobutamine infusion in comparison with PWAO (r = .94). In vitro assessment demonstrated excellent correlation (r = .98, y = 1.0x + 1.94) with little impact of pulse repetition frequency or misalignment up to 30 degrees. Gain dependency was noted but could be optimized by visual inspection of the color image.
CONCLUSIONS: Automatic integration of numerical data within color Doppler flow fields is a feasible new method for quantifying flow. It is simpler and faster, requires fewer assumptions, and uses only one apical view. ACOM is a promising new approach to echocardiographic quantification that deserves further study and refinement.

Entities:  

Keywords:  Non-programmatic

Mesh:

Substances:

Year:  1997        PMID: 9054753     DOI: 10.1161/01.cir.95.4.932

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  10 in total

Review 1.  Three dimensional colour Doppler echocardiography for the characterisation and quantification of cardiac flow events.

Authors:  T Irvine; X N Li; R Rusk; D Lennon; D J Sahn; A Kenny
Journal:  Heart       Date:  2000-11       Impact factor: 5.994

Review 2.  Doppler echocardiographic assessment of valvar regurgitation.

Authors:  James D Thomas
Journal:  Heart       Date:  2002-12       Impact factor: 5.994

3.  Automated cardiac flow measurement by digital colour Doppler echocardiography.

Authors:  T Shiota
Journal:  Heart       Date:  2002-09       Impact factor: 5.994

4.  Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

Authors:  K Dennig; H J Nesser; D Hall; H U Haase; A Schömig
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

5.  Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation.

Authors:  Y Miyake; T Hozumi; I Mori; K Sugioka; A Yamamuro; T Akasaka; S Homma; K Yoshida; J Yoshikawa
Journal:  Heart       Date:  2002-11       Impact factor: 5.994

6.  Stroke volume changes during dobutamine-atropine stress echocardiography: the influence of heart rate and ischaemia.

Authors:  D Poldermans; R Rambaldi; E Boersma; W Vletter; S Carlier; A Elhendy; J J Bax; A J Man in 't Veld; J R Roelandt
Journal:  Int J Card Imaging       Date:  1999-08

7.  Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method.

Authors:  Y Ueda; T Hozumi; K Yoshida; H Watanabe; T Akasaka; T Takagi; A Yamamuro; S Homma; J Yoshikawa
Journal:  Heart       Date:  2002-09       Impact factor: 5.994

8.  Automatic cardiac output measurement (ACOM): clinical applications of a new noninvasive tool.

Authors:  P T Trindade; P Brown; J V Puryear; S Popylisen; I Schnittger
Journal:  Int J Card Imaging       Date:  1998-06

9.  Effects of triiodothyronine replacement therapy in patients with chronic stable heart failure and low-triiodothyronine syndrome: a randomized, double-blind, placebo-controlled study.

Authors:  Ahmad Amin; Mitra Chitsazan; Sepideh Taghavi; Maryam Ardeshiri
Journal:  ESC Heart Fail       Date:  2015-03-30

Review 10.  From left ventricular ejection fraction to cardiac hemodynamics: role of echocardiography in evaluating patients with heart failure.

Authors:  Donato Mele; Aurora Andrade; Paulo Bettencourt; Brenda Moura; Gabriele Pestelli; Roberto Ferrari
Journal:  Heart Fail Rev       Date:  2020-03       Impact factor: 4.214

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.