Literature DB >> 9283548

Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation.

T Shiota1, M Jones, S Aida, H Tsujino, I Yamada, A Delabays, N G Pandian, D J Sahn.   

Abstract

OBJECTIVES: The aim of the present study was to quantitate aortic regurgitant volume and regurgitant fraction in a chronic animal model with surgically created aortic regurgitation using a new semiautomated color Doppler flow calculation method.
BACKGROUND: The conventional noninvasive methods for evaluating the severity of aortic regurgitation have not been accepted widely nor compared with truly quantitative reference standards.
METHODS: Eight to 20 weeks after aortic regurgitation was surgically induced in six sheep, a total of 22 hemodynamic states were studied. Electromagnetic flow probes and meters provided reference flow data. Epicardial color Doppler echocardiographic studies were performed to image left ventricular outflow tract forward and aortic regurgitant blood flows. The new method digitally integrated spatial and temporal color flow velocity data for left ventricular outflow tract forward flow and ascending aortic regurgitant flow. The pulsed Doppler method using the velocity-time integral was also used to obtain regurgitant volumes and regurgitant fractions.
RESULTS: Regurgitant volumes and regurgitant fractions by the new method agreed well with those obtained electromagnetically, whereas the pulsed Doppler method overestimated these reference data (mean [+/-SD] difference 0.23 +/- 2.9 ml vs. 11 +/- 5.8 ml, p < 0.0001 for regurgitant volume; mean difference 1.2 +/- 7.6% vs. 19 +/- 13%, p < 0.0001 for regurgitant fraction).
CONCLUSIONS: This animal study, using strictly quantified aortic regurgitant volumes, demonstrated that the digital color Doppler method provides accurate aortic regurgitant volumes and regurgitant fractions without cumbersome measurements.

Entities:  

Mesh:

Year:  1997        PMID: 9283548     DOI: 10.1016/s0735-1097(97)00210-6

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

1.  Automated cardiac flow measurement by digital colour Doppler echocardiography.

Authors:  T Shiota
Journal:  Heart       Date:  2002-09       Impact factor: 5.994

2.  Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation.

Authors:  Y Miyake; T Hozumi; I Mori; K Sugioka; A Yamamuro; T Akasaka; S Homma; K Yoshida; J Yoshikawa
Journal:  Heart       Date:  2002-11       Impact factor: 5.994

3.  Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method.

Authors:  Y Ueda; T Hozumi; K Yoshida; H Watanabe; T Akasaka; T Takagi; A Yamamuro; S Homma; J Yoshikawa
Journal:  Heart       Date:  2002-09       Impact factor: 5.994

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.