1-60 MHz measurements in focused acoustic fields using spatial averaging corrections.

E G Radulescu1, P A Lewin, A Nowicki.   

Abstract

The purpose of this research was to develop, implement and verify a measurement technique enabling rapid and dependable characterization of ultrasound hydrophone probes beyond 20 MHz. The technique employs focused acoustic sources to optimize signal-to-noise ratio and spatial averaging correction model to account for the finite aperture of the hydrophone probes. To minimize calibration time, substitution technique was chosen and its applicability was tested up to 60 MHz. The overall uncertainty of the measurements was on the order of +/- 1 dB. The results are presented for both needle and membrane type PVDF hydrophones having effective diameters ranging from 130-1200 microns. The fundamental limitations of the technique were determined and it is shown that the spatial averaging error is governed by the cross-section of the beam in the focal plane and the ratio of the effective diameters of the reference and tested hydrophone probes. The technique developed is being extended to frequencies beyond 60 MHz.

Entities:  

Mesh:

Year:  2002        PMID: 12159990     DOI: 10.1016/s0041-624x(02)00166-x

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  13 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

4.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

5.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part II: Validation for ARFI and Pulsed Doppler Waveforms.

Authors:  Keith A Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

6.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

7.  Correction for Spatial Averaging Artifacts in Hydrophone Measurements of High-Intensity Therapeutic Ultrasound: An Inverse Filter Approach.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-24       Impact factor: 2.725

8.  Hydrophone Spatial Averaging Artifacts for ARFI Beams from Array Transducers.

Authors:  Keith Wear; Anant Shah; Aoife M Ivory; Christian Baker
Journal:  IEEE Int Ultrason Symp       Date:  2020

9.  Correction for Spatial Averaging Artifacts for Circularly-Symmetric Pressure Beams Measured with Membrane Hydrophones.

Authors:  Keith Wear; Anant Shah; Christian Baker
Journal:  IEEE Int Ultrason Symp       Date:  2020

10.  Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz.

Authors:  S Umchid; R Gopinath; K Srinivasan; P A Lewin; A S Daryoush; L Bansal; M El-Sherif
Journal:  Ultrasonics       Date:  2008-10-21       Impact factor: 2.890