Literature DB >> 12111135

Towards in vivo nuclear microscopy: iodine-125 imaging in mice using micro-pinholes.

Freek J Beekman1, David P McElroy, Frank Berger, Sanjiv S Gambhir, Edward J Hoffman, Simon R Cherry.   

Abstract

Position-sensitive gamma-radiation detectors equipped with collimators have been used for in vivo imaging of the distribution of radiolabelled molecules in laboratory animals and humans for several decades. To date, the best image resolution achieved in a rodent is on the order of 1 mm. Here we demonstrate how a basic and compact gamma camera can be constructed for in vivo radionuclide imaging in small animals, at much higher spatial resolution. Resolution improvements were obtained by combining dense, shaped, micro-pinhole apertures with iodine-125, an isotope with low energy emissions, ease of incorporation into a wide range of molecules, and straightforward translation into the clinic via other isotopes of iodine that are suitable for nuclear medicine imaging. (125)I images of test distributions and a mouse thyroid have been obtained at a resolution of as high as 200 microm using this simple bench-top camera. Possible future applications and extension to ultra-high-resolution emission tomography are discussed.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12111135     DOI: 10.1007/s00259-002-0805-6

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  14 in total

Review 1.  Single-photon emission computed tomography in neurotherapeutics.

Authors:  Michael D Devous
Journal:  NeuroRx       Date:  2005-04

Review 2.  The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging.

Authors:  Freek Beekman; Frans van der Have
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02       Impact factor: 9.236

3.  Targeting murine heart and brain: visualisation conditions for multi-pinhole SPECT with (99m)Tc- and (123)I-labelled probes.

Authors:  M Pissarek; J Meyer-Kirchrath; T Hohlfeld; S Vollmar; A M Oros-Peusquens; U Flögel; C Jacoby; U Krügel; N Schramm
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-05-07       Impact factor: 9.236

4.  Filled and glycosylated carbon nanotubes for in vivo radioemitter localization and imaging.

Authors:  Sung You Hong; Gerard Tobias; Khuloud T Al-Jamal; Belén Ballesteros; Hanene Ali-Boucetta; Sergio Lozano-Perez; Peter D Nellist; Robert B Sim; Ciara Finucane; Stephen J Mather; Malcolm L H Green; Kostas Kostarelos; Benjamin G Davis
Journal:  Nat Mater       Date:  2010-05-16       Impact factor: 43.841

5.  Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration.

Authors:  Scott D Metzler; Stephen C Moore
Journal:  IEEE Trans Med Imaging       Date:  2019-08-19       Impact factor: 10.048

6.  Design and Feasibility Study of a Single Photon Emission Microscope System for Small Animal I-125 Imaging.

Authors:  L J Meng; N H Clinthorne; S Skinner; R V Hay; M Gross
Journal:  IEEE Trans Nucl Sci       Date:  2006-06-26       Impact factor: 1.679

7.  An Intensified EMCCD Camera for Low Energy Gamma Ray Imaging Applications.

Authors:  L J Meng
Journal:  IEEE Trans Nucl Sci       Date:  2006-08-28       Impact factor: 1.679

8.  Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system.

Authors:  Stephen C Moore; Mi-Ae Park; Zhe Liu; Morgan C Lyon; Lindsay C Johnson; Victor H Lushear; James G Westberg; Scott D Metzler
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

9.  Thick Silicon Double-Sided Strip Detectors for Low-Energy Small-Animal SPECT.

Authors:  Sepideh Shokouhi; Benjamin S McDonald; Heather L Durko; Mark A Fritz; Lars R Furenlid; Todd E Peterson
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

10.  Reproducibility of left ventricular volume and ejection fraction measurements in rat using pinhole gated SPECT.

Authors:  Christian Vanhove; Tony Lahoutte; Michel Defrise; Axel Bossuyt; Philippe R Franken
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-09-15       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.