Thick Silicon Double-Sided Strip Detectors for Low-Energy Small-Animal SPECT.

Sepideh Shokouhi1, Benjamin S McDonald, Heather L Durko, Mark A Fritz, Lars R Furenlid, Todd E Peterson.   

Abstract

This work presents characterization studies of thick silicon double-sided strip detectors for a high-resolution small-animal SPECT. The dimension of these detectors is 60.4 mm × 60.4 mm × 1 mm. There are 1024 strips on each side that give the coordinates of the photon interaction, with each strip processed by a separate ASIC channel. Our measurement shows that intrinsic spatial resolution equivalent to the 59 μm strip pitch is attainable. Good trigger uniformity can be achieved by proper setting of a 4-bit DAC in each ASIC channel to remove trigger threshold variations. This is particularly important for triggering at low energies. The thick silicon DSSD (Double-sided strip detector) shows high potential for small-animal SPECT.

Entities:  

Year:  2009        PMID: 20686626      PMCID: PMC2914306          DOI: 10.1109/TNS.2009.2019106

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  12 in total

1.  Reconstruction of two- and three-dimensional images from synthetic-collimator data.

Authors:  D W Wilson; H H Barrett; E W Clarkson
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

Review 2.  In vivo molecular and genomic imaging: new challenges for imaging physics.

Authors:  Simon R Cherry
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

3.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

4.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging--a simulation study.

Authors:  Zixiong Cao; Girish Bal; Roberto Accorsi; Paul D Acton
Journal:  Phys Med Biol       Date:  2005-09-21       Impact factor: 3.609

5.  On-axis sensitivity and resolution of a slit-slat collimator.

Authors:  Scott D Metzler; Roberto Accorsi; John R Novak; Ahmet S Ayan; Ronald J Jaszczak
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

6.  Front-illuminated versus back-illuminated photon-counting CCD-based gamma camera: important consequences for spatial resolution and energy resolution.

Authors:  Jan W T Heemskerk; Albert H Westra; Peter M Linotte; Kees M Ligtvoet; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2007-03-23       Impact factor: 3.609

7.  Effect of resolution improvement on required count density in ECT imaging: a computer simulation.

Authors:  G Muehllehner
Journal:  Phys Med Biol       Date:  1985-02       Impact factor: 3.609

8.  Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; George A Kastis; Gail D Stevenson; Harrison H Barrett; Lars R Furenlid; Matthew A Kupinski; Dennis D Patton; Donald W Wilson
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

9.  Tomographic Small-Animal Imaging Using a High-Resolution Semiconductor Camera.

Authors:  G A Kastis; M C Wu; S J Balzer; D W Wilson; L R Furenlid; G Stevenson; H B Barber; H H Barrett; J M Woolfenden; P Kelly; M Appleby
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2002-08-07

10.  Radioiodinated aza-diphenylacetylenes as potential SPECT imaging agents for beta-amyloid plaque detection.

Authors:  Wenchao Qu; Mei-Ping Kung; Catherine Hou; Lee-Way Jin; Hank F Kung
Journal:  Bioorg Med Chem Lett       Date:  2007-04-25       Impact factor: 2.823

View more
  5 in total

Review 1.  SPECT detectors: the Anger Camera and beyond.

Authors:  Todd E Peterson; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

2.  High-Resolution Anamorphic SPECT Imaging.

Authors:  Heather L Durko; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2014-06       Impact factor: 1.679

3.  Evaluation of image reconstruction for mouse brain imaging with synthetic collimation from highly multiplexed SiliSPECT projections.

Authors:  S Shokouhi; D W Wilson; S D Metzler; T E Peterson
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

4.  Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Authors:  Lindsay C Johnson; Sepideh Shokouhi; Todd E Peterson
Journal:  IEEE Trans Med Imaging       Date:  2014-07-17       Impact factor: 10.048

5.  Molecular Imaging in the College of Optical Sciences - An Overview of Two Decades of Instrumentation Development.

Authors:  Lars R Furenlid; Harrison H Barrett; H Bradford Barber; Eric W Clarkson; Matthew A Kupinski; Zhonglin Liu; Gail D Stevenson; James M Woolfenden
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-08-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.