Literature DB >> 12093662

Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography.

Andreas U Bayer1, Klaus-Peter Maag, Carl Erb.   

Abstract

PURPOSE: To evaluate the clinical use of a test battery of short-wavelength automated perimetry (SWAP), frequency-doubling technology (FDT) perimetry, and pattern-electroretinography (PERG) in patients with definite primary open-angle glaucoma (POAG) but normal results on standard automated perimetry (SAP). STUDY
DESIGN: Prospective, comparative, observational case series. PARTICIPANTS: Thirty-six patients with POAG with standard visual field defects in one eye and normal standard visual fields in the contralateral eye and 36 normal controls were enrolled. MAIN OUTCOME MEASURES: SWAP, PERG, FDT, and SAP were performed in all eyes, and global indices and amplitudes were used for statistical analysis.
RESULTS: When contralateral POAG eyes with asymmetric glaucomatous damage was compared, a paired t test showed significant differences in SAP mean deviation (MD) (P < 0.0001), SWAP-MD (P = 0.0003), FDT-MD (P = 0.0008), and PERG amplitudes (P < 0.0001). When comparing between POAG eyes with normal results on SAP and normal controls, Student's t test showed significant differences for SWAP-MD (P < 0.0001), FDT-MD (P = 0.0006), PERG N1P1-amplitude (P = 0.0486) and P1N2-amplitude (P < 0.0001); receiver operating characteristic analysis revealed promising accuracy for SWAP-MD of 73.6% (P < 0.0001). SWAP-MD (P < 0.0001) and FDT-MD (P < 0.0001) correlated significantly with SAP-MD and with each other (range, P < 0.0001 to P = 0.0020). Regression analysis revealed that PERG P1N2-amplitude could improve the power of SWAP-MD from 73.6% to detect early POAG in eyes with normal results on SAP to an accuracy of 81.9%.
CONCLUSIONS: A test battery of SWAP-MD and PERG P1N2-amplitude could detect glaucomatous optic neuropathy in POAG eyes with normal standard visual fields, whereas FDT-MD and SWAP-MD significantly correlated with each other and with SAP-MD. All tests were able to detect the eye with the more severe glaucomatous optic neuropathy in patients with asymmetric POAG.

Entities:  

Mesh:

Year:  2002        PMID: 12093662     DOI: 10.1016/s0161-6420(02)01100-4

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  25 in total

1.  Pattern electroretinogram progression in glaucoma suspects.

Authors:  Lori M Ventura; Iuri Golubev; William J Feuer; Vittorio Porciatti
Journal:  J Glaucoma       Date:  2013-03       Impact factor: 2.503

2.  Relative hypersensitivity in healthy eye by frequency doubling perimetry in patients with severely damaged contralateral eye.

Authors:  N Fujimoto; D W Zhang; K Minowa; T Hanawa; O Miyauchi; E Adachi-Usami
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

3.  Normative data for a user-friendly paradigm for pattern electroretinogram recording.

Authors:  Vittorio Porciatti; Lori M Ventura
Journal:  Ophthalmology       Date:  2004-01       Impact factor: 12.079

4.  Different effect of dioptric defocus vs. light scatter on the pattern electroretinogram (PERG).

Authors:  Michael Bach; Marcel Mathieu
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

5.  Progressive loss of retinal ganglion cell function is hindered with IOP-lowering treatment in early glaucoma.

Authors:  Lori M Ventura; William J Feuer; Vittorio Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-02-13       Impact factor: 4.799

6.  Pattern electroretinogram and psychophysical tests of visual function for discriminating between healthy and glaucoma eyes.

Authors:  Ali Tafreshi; Lyne Racette; Robert N Weinreb; Pamela A Sample; Linda M Zangwill; Felipe A Medeiros; Christopher Bowd
Journal:  Am J Ophthalmol       Date:  2010-03       Impact factor: 5.258

7.  Probing glaucoma visual damage by rarebit perimetry.

Authors:  P Brusini; M L Salvetat; L Parisi; M Zeppieri
Journal:  Br J Ophthalmol       Date:  2005-02       Impact factor: 4.638

8.  Electrophysiological assessment of glaucomatous visual dysfunction during treatment with cytidine-5'-diphosphocholine (citicoline): a study of 8 years of follow-up.

Authors:  Vincenzo Parisi
Journal:  Doc Ophthalmol       Date:  2005-01       Impact factor: 2.379

Review 9.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059

10.  Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography.

Authors:  Barbara Cvenkel; Maja Sustar; Darko Perovšek
Journal:  Doc Ophthalmol       Date:  2017-05-31       Impact factor: 2.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.