PURPOSE: To compare the diagnostic accuracy of the pattern electroretinogram (pattern ERG) to that of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry for discriminating between healthy and glaucomatous eyes.
DESIGN: Cross-sectional study.
METHODS: Eighty-three eyes of 42 healthy recruits and 92 eyes of 54 glaucoma patients (based on optic disc appearance) from the University of California, San Diego, Diagnostic Innovations in Glaucoma Study were tested with pattern ERG for glaucoma detection (PERGLA; Lace Elettronica, Pisa, Italy), SAP, SWAP, and FDT within 9 months. Receiver operating characteristic (ROC) curves were generated and compared for pattern ERG amplitude and SAP, SWAP, and FDT mean deviation and pattern standard deviation (PSD). Sensitivities and specificities were compared and agreement among tests was described.
RESULTS: The area under the ROC curve for pattern ERG amplitude was 0.744 (95% confidence interval = 0.670, 0.818). The ROC curve area was 0.786 (0.720, 0.853) for SAP PSD, 0.732 (0.659, 0.806) for SWAP PSD, and 0.818 (0.758, 0.879) for FDT PSD. At 95% specificity, sensitivities of SAP and FDT PSD were significantly higher than that of pattern ERG amplitude; at 80% specificity, similar sensitivities were observed among tests. Agreement among tests was slight to moderate.
CONCLUSION: The diagnostic accuracy of the pattern ERG amplitude was similar to that of SAP and SWAP, but somewhat worse than that of FDT. Nevertheless, the pattern ERG may hold some advantage over psychophysical testing because of its largely objective nature. (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20172073      PMCID: PMC2827352          DOI: 10.1016/j.ajo.2009.09.027

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  36 in total

1.  Color perimetry for assessment of primary open-angle glaucoma.

Authors:  P A Sample; R N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  1990-09       Impact factor: 4.799

2.  Pattern electroretinogram in glaucoma and ocular hypertension.

Authors:  M Bach; A Speidel-Fiaux
Journal:  Doc Ophthalmol       Date:  1989-10       Impact factor: 2.379

3.  The topography of visual evoked response properties across the visual field.

Authors:  H A Baseler; E E Sutter; S A Klein; T Carney
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1994-01

4.  Optimum parameters for short-wavelength automated perimetry.

Authors:  P A Sample; C A Johnson; G Haegerstrom-Portnoy; A J Adams
Journal:  J Glaucoma       Date:  1996-12       Impact factor: 2.503

5.  M and P components of the VEP and their visual field distribution.

Authors:  H A Baseler; E E Sutter
Journal:  Vision Res       Date:  1997-03       Impact factor: 1.886

6.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach.

Authors:  E R DeLong; D M DeLong; D L Clarke-Pearson
Journal:  Biometrics       Date:  1988-09       Impact factor: 2.571

Review 7.  Psychophysical evidence for separate channels for the perception of form, color, movement, and depth.

Authors:  M S Livingstone; D H Hubel
Journal:  J Neurosci       Date:  1987-11       Impact factor: 6.167

8.  Evidence for a ganglion cell contribution to the primate electroretinogram (ERG): effects of TTX on the multifocal ERG in macaque.

Authors:  D C Hood; L J Frishman; S Viswanathan; J G Robson; J Ahmed
Journal:  Vis Neurosci       Date:  1999 May-Jun       Impact factor: 3.241

9.  The pattern electroretinogram in retinal and optic nerve disease. A quantitative comparison of the pattern of visual dysfunction.

Authors:  R Nesher; G L Trick
Journal:  Doc Ophthalmol       Date:  1991       Impact factor: 2.379

Review 10.  Physiology, morphology and spatial densities of identified ganglion cell types in primate retina.

Authors:  D M Dacey
Journal:  Ciba Found Symp       Date:  1994
View more
  12 in total

1.  Pattern electroretinogram progression in glaucoma suspects.

Authors:  Lori M Ventura; Iuri Golubev; William J Feuer; Vittorio Porciatti
Journal:  J Glaucoma       Date:  2013-03       Impact factor: 2.503

2.  Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG Ratio protocols.

Authors:  Michael Bach; Anke Ramharter-Sereinig
Journal:  Doc Ophthalmol       Date:  2013-10-15       Impact factor: 2.379

3.  Electrophysiology and colour: a comparison of methods to evaluate inner retinal function.

Authors:  A Kurtenbach; C Kernstock; E Zrenner; H Langrová
Journal:  Doc Ophthalmol       Date:  2015-09-23       Impact factor: 2.379

4.  Attenuated Amplitude of Pattern Electroretinogram in Glaucoma Patients with Choroidal Parapapillary Microvasculature Dropout.

Authors:  Jiyun Lee; Chan Kee Park; Kyoung In Jung
Journal:  J Clin Med       Date:  2022-04-28       Impact factor: 4.964

5.  Adaptation of the steady-state PERG in early glaucoma.

Authors:  Vittorio Porciatti; Brandon Bosse; Prashant K Parekh; Olga A Shif; William J Feuer; Lori M Ventura
Journal:  J Glaucoma       Date:  2014 Oct-Nov       Impact factor: 2.503

6.  Can Variability of Pattern ERG Signal Help to Detect Retinal Ganglion Cells Dysfunction in Glaucomatous Eyes?

Authors:  Alberto Mavilio; Francesca Scrimieri; Donato Errico
Journal:  Biomed Res Int       Date:  2015-06-08       Impact factor: 3.411

7.  Steady-state pattern electroretinogram and frequency doubling technology in anisometropic amblyopia.

Authors:  Costantino Schiavi; Filippo Tassi; Alessandro Finzi; Ernesto Strobbe; Mauro Cellini
Journal:  Clin Ophthalmol       Date:  2016-10-19

8.  RE-PERG, a new procedure for electrophysiologic diagnosis of glaucoma that may improve PERG specificity.

Authors:  Alberto Mavilio; Dario Sisto; Paolo Ferreri; Nicola Cardascia; Giovanni Alessio
Journal:  Clin Ophthalmol       Date:  2017-01-23

9.  Comparison of pattern electroretinograms of glaucoma patients with parafoveal scotoma versus peripheral nasal step.

Authors:  Kyoung In Jung; Sooji Jeon; Yong Chan Kim; Chan Kee Park
Journal:  Sci Rep       Date:  2019-03-05       Impact factor: 4.379

10.  Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension.

Authors:  Mauro Cellini; Pier Giorgio Toschi; Ernesto Strobbe; Nicole Balducci; Emilio C Campos
Journal:  BMC Ophthalmol       Date:  2012-08-01       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.